3RD-GENERATION GLUCOSE BIOSENSOR INCORPORATED IN A CONDUCTING PRINTING INK

被引:49
作者
KOOPAL, CGJ [1 ]
BOS, AACM [1 ]
NOLTE, RJM [1 ]
机构
[1] NSR CTR,DEPT ORGAN CHEM,6525 ED NIJMEGEN,NETHERLANDS
关键词
D O I
10.1016/0925-4005(94)87077-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor based on a conducting screen-printing ink for the direct amperometric measurement of glucose is described. Carbon electrode prints, containing the work, reference and auxiliary electrodes, are used as the substrate for the sensor. The active parts of the carbon ink are the redox enzyme glucose oxidase and the conducting polymer poly(pyrrole), which can communicate directly with each other. As a result, the biosensor is largely independent of the oxygen concentration. The feasibility of the described biosensor ink for screen printing is shown.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 31 条
[1]   AMPEROMETRIC ENZYME ELECTRODES [J].
ALBERY, WJ ;
BARTLETT, PN ;
CASS, AEG ;
EISENTHAL, R ;
HIGGINS, IJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) :107-119
[2]   MASS-PRODUCTION OF BIOSENSORS [J].
ALVAREZICAZA, M ;
BILITEWSKI, U .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :A525-A533
[3]   DIRECT ELECTROCHEMICAL DETERMINATION OF GLUCOSE-OXIDASE IN BIOLOGICAL SAMPLES [J].
AUBREELECAT, A ;
HERVAGAULT, C ;
DELACOUR, A ;
BEAUDE, P ;
BOURDILLON, C ;
REMY, MH .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :427-430
[4]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[5]   MICROPOROUS ALUMINUM-OXIDE FILMS AT ELECTRODES .7. MEDIATION OF THE CATALYTIC ACTIVITY OF GLUCOSE-OXIDASE VIA LATERAL DIFFUSION OF A FERROCENE AMPHIPHILE IN A BILAYER ASSEMBLY [J].
BOURDILLON, C ;
MAJDA, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (05) :1795-1799
[6]  
Clark L C Jr, 1979, Methods Enzymol, V56, P448
[7]   SCANNING TUNNELING MICROSCOPY STUDY OF POLYPYRROLE FILMS AND OF GLUCOSE-OXIDASE AS USED IN A 3RD-GENERATION BIOSENSOR [J].
CZAJKA, R ;
KOOPAL, CGJ ;
FEITERS, MC ;
GERRITSEN, JW ;
NOLTE, RJM ;
VANKEMPEN, H .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 29 (01) :47-57
[8]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358
[9]  
DELAHAY P, 1965, NEW INSTRUMENTAL MET, P87
[10]  
DICKS JM, 1989, ANN BIOL CLIN-PARIS, V47, P607