BURN WOUND EVAPORATION - MEASUREMENT OF BODY-FLUID LOSS BY PROBE EVAPORIMETER AND WEIGHT CHANGE

被引:11
作者
FERGUSON, JC [1 ]
MARTIN, CJ [1 ]
RAYNER, C [1 ]
机构
[1] UNIV ABERDEEN,DEPT PLAST & RECONSTRUCT SURG,ABERDEEN AB9 2ZD,SCOTLAND
来源
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT | 1991年 / 12卷 / 02期
关键词
D O I
10.1088/0143-0815/12/2/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A knowledge of the rate of fluid loss from the body is a useful aid in planning treatment of patients with severe burns. Different methods for obtaining this data have been investigated. Evaporation rates recorded from a probe evaporimeter have been compared with gravimetric measurements. The evaporimeter underestimated evaporation, especially at high levels, but could be calibrated against known evaporation rates. Estimates of whole-body fluid loss have been made from calibrated evaporimeter data and results compared with measurements of fluid loss by weight change for three patients. Problems with assessing whole-body evaporation rates in the clinical environment are highlighted. Weight change gives a more accurate assessment of total body fluid loss, but considerable effort is necessary to record all relevant information. Probe evaporimeter measurements are simple to perform and allow local evaporation rates to be estimated, but results should be treated with caution. Evaporation rates from wounds of 17 patients with severe burns have been evaluated in terms of surface diffusion resistances. The diffusion resistances of some burn wounds increased with time, but many did not change significantly during the first ten days after injury, and there was considerable variation with burn type and severity.
引用
收藏
页码:143 / 155
页数:13
相关论文
共 19 条
[1]
PERMEABILITY OF THERMALLY DAMAGED SKIN .1. IMMEDIATE INFLUENCES OF 60-DEGREES-C SCALDING ON HAIRLESS MOUSE SKIN [J].
BEHL, CR ;
FLYNN, GL ;
KURIHARA, T ;
SMITH, W ;
GATMAITAN, O ;
HIGUCHI, WI ;
HO, NFH ;
PIERSON, CL .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1980, 75 (04) :340-345
[2]
BEHL CR, 1982, BURNS, V8, P86
[3]
DIFFUSION OF LIQUID WATER THROUGH HUMAN SKIN [J].
BUETTNER, KJK .
JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (02) :261-268
[5]
Clark R.P., 1985, MAN HIS THERMAL ENV
[6]
GUIDE TO RATE OF NON-RENAL WATER LOSS FROM PATIENTS WITH BURNS [J].
DAVIES, JWL ;
LAMKE, LO ;
LILJEDAHL, SO .
BRITISH JOURNAL OF PLASTIC SURGERY, 1974, 27 (04) :325-329
[7]
DAVIES JWL, 1982, PHYSL RESPONSES BURN
[8]
BURN WOUND EVAPORATION - AN EVALUATION OF AIR DIFFUSION RESISTANCES GOVERNING HEAT-TRANSFER IN A CLEAN-AIR UNIT [J].
FERGUSON, JC ;
MARTIN, CJ .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (04) :319-330
[9]
STUDIES IN BURNS .1. WATER LOSS FROM BODY SURFACE [J].
JELENKO, C ;
WHEELER, ML .
ANNALS OF SURGERY, 1967, 165 (01) :83-&
[10]
LAMKE L O, 1971, Scandinavian Journal of Plastic and Reconstructive Surgery, V5, P17