POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF BLOOD-TO-BRAIN AND BLOOD-TO-TUMOR TRANSPORT OF RB-82 .2. CLINICAL-DATA AND VALIDATION OF TECHNIQUE

被引:10
作者
DHAWAN, V [1 ]
JARDEN, JO [1 ]
MOELLER, JR [1 ]
STROTHER, SC [1 ]
ROTTENBERG, DA [1 ]
机构
[1] MEM SLOAN KETTERING CANC CTR, DEPT NEUROL, NEW YORK, NY 10021 USA
关键词
D O I
10.1088/0031-9155/34/12/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:1785 / 1794
页数:10
相关论文
共 16 条
[1]   TRANSPORT OF ALPHA-AMINOISOBUTYRIC-ACID ACROSS BRAIN CAPILLARY AND CELLULAR MEMBRANES [J].
BLASBERG, RG ;
FENSTERMACHER, JD ;
PATLAK, CS .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (01) :8-32
[2]   QUANTITATIVE MEASUREMENT OF BLOOD-BRAIN-BARRIER PERMEABILITY USING RUBIDIUM-82 AND POSITRON EMISSION TOMOGRAPHY [J].
BROOKS, DJ ;
BEANEY, RP ;
LAMMERTSMA, AA ;
LEENDERS, KL ;
HORLOCK, PL ;
KENSETT, MJ ;
MARSHALL, J ;
THOMAS, DG ;
JONES, T .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (04) :535-545
[3]   EFFECT OF BLOOD CURVE SMEARING ON THE ACCURACY OF PARAMETER ESTIMATES OBTAINED FOR RB-82/PET STUDIES OF BLOOD-BRAIN BARRIER PERMEABILITY [J].
DHAWAN, V ;
JARDEN, JO ;
STROTHER, S ;
ROTTENBERG, DA .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :61-74
[4]   POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF BLOOD-TO-BRAIN AND BLOOD-TO-TUMOR TRANSPORT OF RB-82 .1. ERROR ANALYSIS AND COMPUTER-SIMULATIONS [J].
DHAWAN, V ;
POLTORAK, A ;
MOELLER, JR ;
JARDEN, JO ;
STROTHER, SC ;
THALER, H ;
ROTTENBERG, DA .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12) :1773-1784
[5]   QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES [J].
FRACKOWIAK, RSJ ;
LENZI, GL ;
JONES, T ;
HEATHER, JD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :727-736
[6]   THE TIME COURSE OF STEROID ACTION ON BLOOD-TO-BRAIN AND BLOOD-TO-TUMOR TRANSPORT OF RB-82 - A POSITRON EMISSION TOMOGRAPHIC STUDY [J].
JARDEN, JO ;
DHAWAN, V ;
MOELLER, JR ;
STROTHER, SC ;
ROTTENBERG, DA .
ANNALS OF NEUROLOGY, 1989, 25 (03) :239-245
[7]   POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF BLOOD-TO-BRAIN AND BLOOD-TO-TUMOR TRANSPORT OF RB-82 - THE EFFECT OF DEXAMETHASONE AND WHOLE-BRAIN RADIATION-THERAPY [J].
JARDEN, JO ;
DHAWAN, V ;
POLTORAK, A ;
POSNER, JB ;
ROTTENBERG, DA .
ANNALS OF NEUROLOGY, 1985, 18 (06) :636-646
[8]   EVALUATION OF THE PERFORMANCE-CHARACTERISTICS OF THE PC 4600 POSITRON EMISSION TOMOGRAPH [J].
KEARFOTT, KJ ;
CARROLL, LR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) :502-513
[9]   A METHOD TO QUANTITATE THE FRACTIONAL EXTRACTION OF RUBIDIUM-82 ACROSS THE BLOOD-BRAIN-BARRIER USING POSITRON EMISSION TOMOGRAPHY [J].
LAMMERTSMA, AA ;
BROOKS, DJ ;
FRACKOWIAK, RSJ ;
HEATHER, JD ;
JONES, T .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (04) :523-534
[10]   CEREBRAL BLOOD-VOLUME MEASURED WITH INHALED (CO)-O-15 AND POSITRON EMISSION TOMOGRAPHY [J].
MARTIN, WRW ;
POWERS, WJ ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (04) :421-426