CAPILLARY ZONE ELECTROPHORESIS WITH A LINEAR, NON-CROSS-LINKED POLYACRYLAMIDE-GEL - SEPARATION OF PROTEINS ACCORDING TO MOLECULAR MASS

被引:95
作者
WIDHALM, A
SCHWER, C
BLAAS, D
KENNDLER, E
机构
[1] UNIV VIENNA,INST ANALYT CHEM,WAHRINGERSTR 38,A-1090 VIENNA,AUSTRIA
[2] UNIV VIENNA,FAC MED,INST BIOCHEM,A-1090 VIENNA,AUSTRIA
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 549卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(00)91458-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation of proteins according to their molecular masses using capillary zone electrophoresis was demonstrated in a buffer containing a linear, non-cross-linked polyacrylamide gel as a sieving medium. The four test proteins, covering a molecular mass range of between 17 800 and 77 000, were applied as sodium dodecyl sulphate (SDS) complexes. The separation was carried out at pH 5.5 (phosphate buffer, 0.5% SDS, 10% liquid, linear polyacrylamide gel). The retention times of the proteins correlated with the logarithm of their molecular masses.
引用
收藏
页码:446 / 451
页数:6
相关论文
共 10 条
[2]   USE OF LIQUID POLYACRYLAMIDE IN ELECTROPHORESIS .3. PROPERTIES OF LIQUID POLYACRYLAMIDE IN THE PRESENCE OF CELLULOSE-ACETATE [J].
BODE, HJ .
ANALYTICAL BIOCHEMISTRY, 1979, 92 (01) :99-110
[3]   USE OF LIQUID POLYACRYLAMIDE IN ELECTROPHORESIS .1. MIXED GELS COMPOSED OF AGAR-AGAR AND LIQUID POLYACRYLAMIDE [J].
BODE, HJ .
ANALYTICAL BIOCHEMISTRY, 1977, 83 (01) :204-210
[4]  
BODE HJ, 1978, H-S Z PHYSIOL CHEM, V359, P1237
[5]   HIGH-PERFORMANCE SODIUM DODECYL-SULFATE POLYACRYLAMIDE-GEL CAPILLARY ELECTROPHORESIS OF PEPTIDES AND PROTEINS [J].
COHEN, AS ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1987, 397 :409-417
[6]   SEPARATION OF DNA RESTRICTION FRAGMENTS BY HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS WITH LOW AND ZERO CROSS-LINKED POLYACRYLAMIDE USING CONTINUOUS AND PULSED ELECTRIC-FIELDS [J].
HEIGER, DN ;
COHEN, AS ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :33-48
[7]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - THE ELECTROPHORETIC COUNTERPART OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :1-6
[9]  
PAULUS A, 1988, 6TH INT S IS CAP ZON
[10]   FACTORS AFFECTING FREE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN CAPILLARY ELECTROPHORESIS [J].
ZHU, MD ;
HANSEN, DL ;
BURD, S ;
GANNON, F .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :311-319