THERMOELECTRIC ENZYME SENSOR FOR MEASURING BLOOD-GLUCOSE

被引:25
作者
MUEHLBAUER, MJ [1 ]
GUILBEAU, EJ [1 ]
TOWE, BC [1 ]
BRANDON, TA [1 ]
机构
[1] ARIZONA STATE UNIV,DEPT CHEM BIOL & MAT ENGN,TEMPE,AZ 85227
关键词
blood glucose; calorimetric; catalase; catheter; enzyme; glucose oxidase; implantation; stability; thermoelectric; thermopile;
D O I
10.1016/0956-5663(90)80022-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new calorimetric sensor has been developed which employs a thin-film thermopile in association with an immobilized enzyme. The thermopile detects the minute temperature rise that occurs when a specific chemical substrate is catalyzed by the enzyme. A prototype sensor is described which generates an equivalent proportional voltage response to glucose concentrations present in either buffer solution or blood. These sensors have remained useful for up to 18 days when operated intermittently for measuring glucose in buffer solutions, or for up to 4 days when operated continuously. When implanted inside cardiovascular shunts on anesthetized dogs, the sensors responded appropriately to changes in the blood glucose concentration. © 1989.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 11 条
[1]   MACROKINETICS AND OPERATIONAL STABILITY OF IMMOBILIZED GLUCOSE OXIDASE AND CATALASE [J].
BUCHHOLZ, K ;
GODELMANN, B .
BIOTECHNOLOGY AND BIOENGINEERING, 1978, 20 (08) :1201-1220
[2]   THERMAL ENZYME PROBE WITH DIFFERENTIAL TEMPERATURE-MEASUREMENTS IN A LAMINAR FLOW-THROUGH CELL [J].
FULTON, SP ;
COONEY, CL ;
WEAVER, JC .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :505-508
[3]  
GUILBEAU EJ, 1988, T AM SOC ART INT ORG, V33, P329
[4]  
IRELAND TW, 1988, THESIS ARIZONA STATE
[5]   MODEL FOR A THERMOELECTRIC ENZYME GLUCOSE SENSOR [J].
MUEHLBAUER, MJ ;
GUILBEAU, EJ ;
TOWE, BC .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :77-83
[6]   DEVELOPMENT AND APPLICATION OF A THERMISTOR ENZYME PROBE IN THE UREA-UREASE SYSTEM [J].
RICH, S ;
IANNIELLO, RM ;
JESPERSEN, ND .
ANALYTICAL CHEMISTRY, 1979, 51 (02) :204-206
[7]   TELEMETRY GLUCOSE MONITORING DEVICE WITH NEEDLE-TYPE GLUCOSE SENSOR - A USEFUL TOOL FOR BLOOD-GLUCOSE MONITORING IN DIABETIC INDIVIDUALS [J].
SHICHIRI, M ;
ASAKAWA, N ;
YAMASAKI, Y ;
KAWAMORI, R ;
ABE, H .
DIABETES CARE, 1986, 9 (03) :298-301
[8]  
SHICHIRI M, 1984, BIOMED BIOCHIM ACTA, V5, P561
[9]  
TRAN-MINH C, 1978, Analytical Chemistry, V50, P1874
[10]   TIME-DEPENDENT INACTIVATION OF IMMOBILIZED GLUCOSE-OXIDASE AND CATALASE [J].
TSE, PHS ;
GOUGH, DA .
BIOTECHNOLOGY AND BIOENGINEERING, 1987, 29 (06) :705-713