CATHETER ABLATION OF THE ATRIOVENTRICULAR JUNCTION USING A HELICAL MICROWAVE ANTENNA - A NOVEL MEANS OF COUPLING ENERGY TO THE ENDOCARDIUM

被引:41
作者
LANGBERG, JJ
WONNELL, T
CHIN, MC
FINKBEINER, W
SCHEINMAN, M
STAUFFER, P
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT CHEM,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT RADIAT ONCOL,SAN FRANCISCO,CA 94143
[3] UNIV CALIF SAN FRANCISCO,DEPT PATHOL,SAN FRANCISCO,CA 94143
[4] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 12期
关键词
CATHETER ABLATION; ATRIOVENTRICULAR BLOCK; HYPERTHERMIA; MICROWAVE;
D O I
10.1111/j.1540-8159.1991.tb06481.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Catheter ablation with either direct current defibrillator discharges or radiofrequency energy produces tissue injury via current flow from an electrode into the adjacent myocardium. In order to affect tissue at a distance, excessive power density may be produced at the electrode-tissue interface with the possibility of explosive gas formation or coagulum formation. A novel microwave catheter was developed with a helical antenna distally. This coil, although not in direct contact with the endocardium, radiates an electromagnetic field into the tissue that, in turn, causes thermal injury. The utility of this system for ablation was assessed in six dogs. The antenna catheter was introduced percutaneously and positioned so as to record the largest His electrogram. Microwave power (50 watts at 2,450 MHz) was applied for 114 +/- 118 seconds. Complete AV block was produced in all six animals with 1.8 +/- 1.2 applications. There was no ventricular ectopy or change in blood pressure during microwave ablation. One dog died 6 days after ablation. The remaining five dogs had persistent, complete AV block during 6 weeks of follow-up. Pathological analysis at 6 weeks revealed a large (mean 2.8 x 4.7 mm) fibrovascular scar in the region of the AV junction. Percutaneous microwave ablation of the endocardium appears feasible. By radiating an electromagnetic field without direct contact, this system can produce large lesions without being limited by desiccation of tissue and impedance rise.
引用
收藏
页码:2105 / 2113
页数:9
相关论文
共 27 条
  • [1] BECKMAN KJ, 1987, CIRCULATION, V76, P405
  • [2] DIAGNOSIS AND CURE OF THE WOLFF-PARKINSON-WHITE SYNDROME OR PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIAS DURING A SINGLE ELECTROPHYSIOLOGIC TEST
    CALKINS, H
    SOUSA, J
    ELATASSI, R
    ROSENHECK, S
    DEBUITLEIR, M
    KOU, WH
    KADISH, AH
    LANGBERG, JJ
    MORADY, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) : 1612 - 1618
  • [3] COHEN JJ, IN PRESS CIRCULATION
  • [4] SOME ASPECTS OF OPTIMIZATION OF AN INVASIVE MICROWAVE ANTENNA FOR LOCAL HYPERTHERMIA TREATMENT OF CANCER
    DESIEYES, DC
    DOUPLE, EB
    STROHBEHN, JW
    TREMBLY, BS
    [J]. MEDICAL PHYSICS, 1981, 8 (02) : 174 - 183
  • [5] THE PERCUTANEOUS CARDIAC MAPPING AND ABLATION REGISTRY - FINAL SUMMARY OF RESULTS
    EVANS, GT
    SCHEINMAN, MM
    SCHEINMAN, MM
    ZIPES, DP
    BENDITT, D
    BREITHARDT, G
    CAMM, AJ
    ELSHERIF, N
    FISHER, J
    FONTAINE, G
    LEVY, S
    PRYSTOWSKY, E
    JOSEPHSON, M
    MORADY, F
    RUSKIN, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1621 - 1626
  • [6] FONTAINE G, 1987, ABLATION CARDIAC ARR, P371
  • [7] TISSUE HEATING DURING RADIOFREQUENCY CATHETER ABLATION - A THERMODYNAMIC MODEL AND OBSERVATIONS IN ISOLATED PERFUSED AND SUPERFUSED CANINE RIGHT VENTRICULAR FREE WALL
    HAINES, DE
    WATSON, DD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (06): : 962 - 976
  • [8] HAINES DE, 1989, CIRCULATION, V8, P41
  • [9] PROARRHYTHMIC EFFECTS OF VENTRICULAR ELECTRICAL CATHETER ABLATION IN DOGS
    HAUER, RNW
    DEMEDINA, EOR
    BORST, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (06) : 1350 - 1356
  • [10] Hoyt RH, 1986, J APPL CARDIOL, V1, P469