ANALYSIS OF PULMONARY ARTERIAL-PRESSURE PROFILE AFTER OCCLUSION OF PULSATILE BLOOD-FLOW

被引:29
作者
MAAREK, JMI
HAKIM, TS
CHANG, HK
机构
[1] UNIV SO CALIF,DEPT BIOMED ENGN,LOS ANGELES,CA 90089
[2] SUNY UPSTATE HOSP,SCH MED,DEPT SURG,SYRACUSE,NY 13210
关键词
arterial occlusion; double occlusion; isolated lung; modeling; pulmonary capillary pressure; pulmonary vascular bed; pulsatility;
D O I
10.1152/jappl.1990.68.2.761
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In isolated canine lung lobes perfused with a pulsatile pump, arterial occlusions were performed and the postocclusion arterial pressure profiles were analyzed to estimate the pulmonary capillary pressure. A solenoid valve interposed between the pump and the lobar artery was used to perform arterial occlusions at several instants equally distributed within a pressure cycle. Double occlusions were also accomplished by simultaneously activating the solenoid valve and clamping the venous outflow of the lung lobe. To analyze an arterial occlusion pressure profile, we computed the best monoexponential fit of the pressure decay over a short period of time after the occlusion maneuvers. Two estimates of the capillary pressure were derived from this analysis: 1) the extrapolation of the exponential fit to the instant of occlusion, and 2) the point at which the recorded pressure decay curve merges with the exponential fit. The pressures thus determined were compared with the double occlusion pressure that provided an independent estimate of the pulmonary capillary pressure. Our results show that, under a wide range of conditions, the estimates of the capillary pressure obtained from the arterial occlusion data are nearly equal to the double occlusion pressures. Additionally, we estimated the capillary pressure variations within a pressure cycle by examining the occlusion pressures sampled at different instants of the cycle. The pulsatility of the pulmonary microvascular pressure varied with the pump frequency as well as the state of arterial and venous vasoaction. These variations are consistent with the representation of the lung vasculature as a low-pass filter.
引用
收藏
页码:761 / 769
页数:9
相关论文
共 27 条
[1]   ARTERIAL-OCCLUSION VERSUS ISOFILTRATION PULMONARY CAPILLARY PRESSURES DURING VERY HIGH FLOW [J].
BSHOUTY, Z ;
ALI, J ;
YOUNES, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (03) :1174-1178
[2]   BEDSIDE MEASUREMENT OF PULMONARY CAPILLARY-PRESSURE IN PATIENTS WITH ACUTE RESPIRATORY-FAILURE [J].
COLLEE, GG ;
LYNCH, KE ;
HILL, RD ;
ZAPOL, WM .
ANESTHESIOLOGY, 1987, 66 (05) :614-620
[3]   MEASUREMENT OF EFFECTIVE PULMONARY CAPILLARY-PRESSURE USING THE PRESSURE PROFILE AFTER PULMONARY-ARTERY OCCLUSION [J].
COPE, DK ;
ALLISON, RC ;
PARMENTIER, JL ;
MILLER, JN ;
TAYLOR, AE .
CRITICAL CARE MEDICINE, 1986, 14 (01) :16-22
[4]   PULMONARY MICRO-CIRCULATORY HEMODYNAMICS [J].
DAWSON, CA ;
LINEHAN, JH ;
RICKABY, DA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1982, 384 (MAY) :90-106
[5]   EFFECTS OF ESCHERICHIA-COLI ENDOTOXIN ON PULMONARY VASCULAR-RESISTANCE IN INTACT DOGS [J].
DORIO, V ;
HALLEUX, J ;
RODRIGUEZ, LM ;
WAHLEN, C ;
MARCELLE, R .
CRITICAL CARE MEDICINE, 1986, 14 (09) :802-806
[6]  
GAAR KA, 1967, AM J PHYSIOL, V213, P910
[7]  
GRIMBERT FA, 1988, EUR RESPIR J, V1, P297
[9]   ESTIMATION OF PULMONARY CAPILLARY-PRESSURE IN INTACT DOG LUNGS USING THE ARTERIAL-OCCLUSION TECHNIQUE [J].
HAKIM, TS ;
MAAREK, JMI ;
CHANG, HK .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (01) :217-224
[10]   PARTITIONING OF PULMONARY VASCULAR-RESISTANCE IN DOGS BY ARTERIAL AND VENOUS OCCLUSION [J].
HAKIM, TS ;
MICHEL, RP ;
CHANG, HK .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (03) :710-715