INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETERMINATION OF GOLD IN SERUM - COMPARISON WITH FLAME AND FURNACE ATOMIC-ABSORPTION SPECTROMETRY

被引:15
作者
HIGASHIURA, M
UCHIDA, H
UCHIDA, T
WADA, H
机构
[1] IND RES INST,YOKOHAMA,KANAGAWA 236,JAPAN
[2] NAGOYA INST TECHNOL,DEPT APPL CHEM,ANALYT CHEM LAB,SHOWA KU,NAGOYA,AICHI 466,JAPAN
关键词
INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY; ATOMIC ABSORPTION SPECTROMETRY; GOLD; SERUM;
D O I
10.1016/0003-2670(94)00630-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three analytical methods for the determination of gold in the serum of rheumatoid patients have been compared, i.e., flame and graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry (ICP-MS) with the respective detection limits of 30, 1.0 and 0.01 ng ml(-1). The stability of gold solutions was also investigated. With 0.1% Triton X-100 and 0.1 M hydrochloric acid the gold concentration at ng ml(-1) levels in standards was constant for 4 days, and the levels in 2000-fold diluted serum were the same for at least 7 days. The analytical results obtained with the above three methods correlated quite well, however, ICP-MS was the best technique, because of its specificity, sensitivity, wide dynamic range, speedy and ease of measurement.
引用
收藏
页码:317 / 321
页数:5
相关论文
共 23 条
  • [1] DETERMINATION OF IODINE AND BROMINE IN PLASMA AND URINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    ALLAIN, P
    MAURAS, Y
    DOUGE, C
    JAUNAULT, L
    DELAPORTE, T
    BEAUGRAND, C
    [J]. ANALYST, 1990, 115 (06) : 813 - 815
  • [2] [Anonymous], 1960, ANN RHEUM DIS, V19, P95
  • [3] BERTAGNOLLI JA, 1993, ATOM SPECTROSC, V14, P4
  • [4] CASETTA B, 1991, ATOM SPECTROSC, V12, P81
  • [5] SERUM GOLD .1. ESTIMATION BY ATOMIC-ABSORPTION SPECTROSCOPY
    DIETZ, AA
    RUBINSTEIN, HM
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1973, 32 (02) : 124 - 127
  • [6] DUNCKLEY JV, 1971, CLIN CHEM, V17, P992
  • [7] Forestier J, 1935, J LAB CLIN MED, V20, P827
  • [8] DOUBLE-BLIND TRIAL OF HIGH VERSUS CONVENTIONAL DOSAGES OF GOLD SALTS FOR RHEUMATOID-ARTHRITIS
    FURST, DE
    LEVINE, S
    SRINIVASAN, R
    METZGER, AL
    BANGERT, R
    PAULUS, HE
    [J]. ARTHRITIS AND RHEUMATISM, 1977, 20 (08): : 1473 - 1480
  • [9] MEASUREMENT OF STABLE ISOTOPES OF BROMINE IN BIOLOGICAL-FLUIDS WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    JANGHORBANI, M
    DAVIS, TA
    TING, BTG
    [J]. ANALYST, 1988, 113 (03) : 405 - 411
  • [10] ELIMINATION OF CHLORIDE INTERFERENCE ON THE DETERMINATION OF SELENIUM IN SERUM BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    LYON, TDB
    FELL, GS
    HUTTON, RC
    EATON, AN
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) : 601 - 603