NON-INVASIVE ASSESSMENT OF SURGICAL SYSTEMIC TO PULMONARY-ARTERY SHUNTS BY RANGE-GATED PULSED DOPPLER ECHOCARDIOGRAPHY

被引:13
作者
ALLEN, HD
SAHN, DJ
LANGE, L
GOLDBERG, SJ
机构
[1] Department of Pediatrics, University of Arizona Health Sciences Center, Tucson, AZ
关键词
D O I
10.1016/S0022-3476(79)80579-X
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Suprasternal range-gated pulsed Doppler echocardiography was used to evaluate surgical shunt patency in children with cyanotic congenital heart disease and right ventricular outflow obstruction following systemic artery to pulmonary artery anastomoses. Normal patients had laminar Doppler auditory signals and time interval histogram flow patterns because right pulmonary artery turbulence was not present during systole or diastole. Patients with pulmonary valvar stenosis had turbulence during systole only. In all nine postoperative patients with surgical shunts, turbulent systolic and diastolic time interval histograms and abnormal auditory signals were present. A typical shunt murmur was not audible to auscultation in six of the postsurgical patients at the time of the study. Suprasternal range-gated pulsed Doppler echocardiography affords an accurate, safe and simple noninvasive bedside means for confirming shunt patency in patients who have undergone surgical systemic artery to pulmonary artery anastomoses. © 1979 The C. V. Mosby Co.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 6 条
  • [1] SUPRASTERNAL NOTCH ECHOCARDIOGRAPHY - ASSESSMENT OF ITS CLINICAL UTILITY IN PEDIATRIC CARDIOLOGY
    ALLEN, HD
    GOLDBERG, SJ
    SAHN, DJ
    OVITT, TW
    GOLDBERG, BB
    [J]. CIRCULATION, 1977, 55 (04) : 605 - 612
  • [2] QUANTITATIVE RADIONUCLIDE ANGIOCARDIOGRAPHY - DETECTION AND QUANTITATION OF LEFT TO RIGHT SHUNTS
    ASKENAZI, J
    AHNBERG, DS
    KORNGOLD, E
    LAFARGE, CG
    MALTZ, DL
    TREVES, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (03) : 382 - 387
  • [3] BAKER DW, 1975, CARDIAC ULTRASOUND
  • [4] DOPPLER ECHOCARDIOGRAPHY - LOCALIZATION OF CARDIAC MURMURS
    JOHNSON, SL
    BAKER, DW
    LUTE, RA
    DODGE, HT
    [J]. CIRCULATION, 1973, 48 (04) : 810 - 822
  • [5] DOPPLER ECHOCARDIOGRAPHY - USE OF A GRAPHICAL DISPLAY SYSTEM
    LORCH, G
    RUBENSTEIN, S
    BAKER, D
    DOOLEY, T
    DODGE, H
    [J]. CIRCULATION, 1977, 56 (04) : 576 - 585
  • [6] DIFFERENTIATION OF VENTRICULAR SEPTAL-DEFECTS FROM MITRAL REGURGITATION BY PULSED DOPPLER ECHOCARDIOGRAPHY
    STEVENSON, JG
    KAWABORI, I
    GUNTHEROTH, WG
    [J]. CIRCULATION, 1977, 56 (01) : 14 - 18