INCREASING THERMOSPRAY RESPONSE FOR CORTISOL BY DERIVATIZATION

被引:35
作者
PAULSON, J
LINDBERG, C
机构
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 554卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)88445-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The 21-hydroxyl group of cortisol was selectively acetylated under mild conditions without affecting the more sterically hindered 11-beta- and 17-alpha-hydroxyl groups. The reaction was performed with a mixture of acetic anhydride and triethylamine in acetonitrile and was complete in less than 15 min at room temperature. The thermospray mass spectrum of cortisol 21-acetate showed minimal fragmentation with the [M + H]+ ion as the base peak. High sensitivity was achieved for acetylated cortisol during selected ion monitoring, the signal-to-noise ratio being increased by a factor of about 4, compared to underivatized cortisol. The limit of detection of cortisol 21-acetate was estimated at 0.24 pmol injected, making thermospray liquid chromatography-mass spectrometry competitive with gas chromatography-mass spectrometry for the determination of cortisol in biological fluids.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 22 条
  • [1] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF PROSTAGLANDIN METHYL-ESTER DERIVATIVES - APPLICATION TO THE DETERMINATION OF PROSTAGLANDIN-E2 AND PROSTAGLANDIN-D2 IN RAT GASTRIC-MUCOSA
    ABIAN, J
    BULBENA, O
    GELPI, E
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 215 - 219
  • [2] PLASMA CORTISOL DETERMINATION BY MASS FRAGMENTOGRAPHY
    BJORKHEM, I
    BLOMSTRAND, R
    LANTTO, O
    LOF, A
    SVENSSON, L
    [J]. CLINICA CHIMICA ACTA, 1974, 56 (03) : 241 - 248
  • [3] BOWERS LD, 1989, CLIN CHEM, V35, P1282
  • [4] DIRECT LIQUID INTRODUCTION THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    COVEY, T
    HENION, J
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (14) : 2275 - 2280
  • [5] COMPARISON OF METHANOL THERMOSPRAY (FILAMENT ON) AND DIRECT CHEMICAL IONIZATION MASS-SPECTROMETRY TO THE STUDY OF BIOLOGICALLY-ACTIVE STEROIDS
    DAS, PR
    PRAMANIK, BN
    MALCHOW, RD
    NG, KJ
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (05): : 253 - 255
  • [6] STABLE ISOTOPE-DILUTION METHOD USING THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY FOR QUANTIFICATION OF DAILY CORTISOL PRODUCTION IN HUMANS
    ESTEBAN, NV
    YERGEY, AL
    LIBERATO, DJ
    LOUGHLIN, T
    LORIAUX, DL
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (11): : 603 - 608
  • [7] DETERMINATION OF SERUM CORTISOL BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - COMPARISON WITH GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    GASKELL, SJ
    ROLLINS, K
    SMITH, RW
    PARKER, CE
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1987, 14 (12): : 717 - 722
  • [8] GASKELL SJ, 1983, CLIN CHEM, V29, P862
  • [9] GOODLEY PC, 1986, COMPILATION THERMOSP
  • [10] DETERMINATION OF CORTISOL IN HUMAN-PLASMA BY CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY USING [H-2(5)] CORTISOL AS AN INTERNAL STANDARD
    HIROTA, N
    FURUTA, T
    KASUYA, Y
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (02): : 237 - 243