MULTIELEMENT DETECTION FOR SUPERCRITICAL FLUID CHROMATOGRAPHY BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:31
作者
CAREY, JM [1 ]
VELA, NP [1 ]
CARUSO, JA [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; SUPERCRITICAL FLUID CHROMATOGRAPHY; MULTIELEMENT DETECTION; ORGANOMETALLIC COMPOUNDS;
D O I
10.1039/ja9920701173
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of multi-element detection using supercritical fluid chromatography (SFC) with inductively coupled plasma mass spectrometry (ICP-MS) has been investigated for organomercury and organolead compounds. Since a quadrupole mass spectrometer is a sequential instrument. multi-element detection of transient signals presents difficulties; therefore, detection is usually performed in a single-ion monitoring mode. The applicability of utilizing time-resolved acquisition (TRA) software for quantitative determinations using SFC was investigated and compared with results obtained for single-ion monitoring modes. Detection limits were found to be approximately 5-10 pg for diethylmercury (DIEM) using TRA detection and 3 pg using single-ion monitoring detection. The detection limits of tetrabutyllead (TTBL) and tributyllead (TRBL) acetate were found to be 0.7-3 and 50-100 pg, respectively, for the TRA acquisitions, and 0.5 and 10 pg for single-ion monitoring measurements. The calibration graphs were linear over three decades for DIEM and TTBL, and two decades for the TRBL. The precision of the technique was between 1 and 5% relative standard deviation for 5 ng injections of the compounds of interest. The accuracy of the SFC-ICP-MS single-ion monitoring technique was demonstrated by analysis of a National Institute of Standards and Technology (NIST) standard reference material (SRM) 2715 Lead in Reference Fuel, giving a concentration of 785+/-9.71 ppm of tetraethyllead, with the SFC-ICP-MS system, compared with the certified value of 784+/-4.00 ppm at the 95% confidence level.
引用
收藏
页码:1173 / 1181
页数:9
相关论文
共 28 条
[1]   LEAD SPECIATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
ALRASHDAN, A ;
VELA, NP ;
CARUSO, JA ;
HEITKEMPER, DT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :551-555
[2]  
BEOCHX RL, 1986, ANAL CHEM, V56, pA274
[3]   POST-COLUMN ETHYLATION FOR THE DETERMINATION OF IONIC ALKYLLEAD COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATOMIC-ABSORPTION SPECTROMETRY [J].
BLAIS, JS ;
MARSHALL, WD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :641-645
[4]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[5]   VERSATILE COMPUTER-CONTROLLED INTERFACE SYSTEM FOR DIRECTLY COUPLED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
EBDON, L ;
ALONSO, JIG ;
HILL, S ;
HOPKINS, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :395-399
[6]   DETERMINATION OF PB2+ IN WATER BY ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY OF TETRAETHYLLEAD FORMED BY REACTION WITH SODIUM TETRAETHYLBORATE [J].
FELDMAN, BJ ;
MOGADEDDI, H ;
OSTERLOH, JD .
JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2) :275-282
[8]   EVALUATION OF INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY AS AN ELEMENT-SPECIFIC DETECTOR FOR SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
FORBES, KA ;
VECCHIARELLI, JF ;
UDEN, PC ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :2033-2037
[9]   INTERFACING OF INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY TO SUPERCRITICAL FLUID CHROMATOGRAPHY FOR ELEMENTAL DETECTION [J].
FUJIMOTO, C ;
YOSHIDA, H ;
JINNO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 411 :213-220
[10]  
FUJIMOTO C, 1990, J MICROCOLUMN SEP, V2, P146