HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS ON DEFORMED NONPOROUS AGAROSE BEADS - FAST BORONATE AFFINITY-CHROMATOGRAPHY OF HEMOGLOBIN AT NEUTRAL PH

被引:39
作者
HJERTEN, S
LI, JP
机构
[1] Institute of Biochemistry, University of Uppsala, Biomedical Centre, S-751 23 Uppsala
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 500卷
关键词
D O I
10.1016/S0021-9673(00)96091-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aminophenylboronic acid was attached to epoxy-activated non-porous agarose beads with diameters of 12-15 μm and this boronate gel column was used for the fractionation of glycosylated from non-glycosylated haemoglobin. By varying the experimental conditions it was shown that the ratio between the second peak (glycosylated haemoglobin) and the first peak (non-glycosylated haemoglobin) was virtually independent of pH in the range 7-8, ionic strength, flow-rate and sample load (up to at least 160 μl ofhaemolysate on a 0.7-ml column). It is therefore not necessary to control thoroughly these parameters in order to obtain reproducible results, which is a great advantage in fast routine analyses of glycosylated haemoglobin. At a flow-rate of 4.0 ml/min an analysis was finished within 2 min on a 2.5 cm X 0.6 cm I.D. column. The total time of an analysis was also short because a sample from a droplet of blood could be applied directly onto the column after haemolysis for 1 min without removal of cell debris by time-consuming centrifugation. The experiments were performed at a pH close to the isoelectric point of haemoglobin, because at this pH haemoglobin has a negligible net charge and will therefore not interact with the charged groups of the ligands, the matrix and proteins adsorbed in previous runs. © 1990.
引用
收藏
页码:543 / 553
页数:11
相关论文
共 20 条
[1]  
BERGOLD A, 1983, CHEM ANAL, V66, P149
[2]   HEMOGLOBIN-A1C LEVELS IN CHILDREN AND ADOLESCENTS WITH DIABETES-MELLITUS [J].
GOLDSTEIN, DE ;
WALKER, B ;
RAWLINGS, SS ;
HESS, RL ;
ENGLAND, JD ;
PETH, SB ;
HEWETT, JE .
DIABETES CARE, 1980, 3 (04) :503-507
[3]  
Goldstein DE, 1982, DIABETES S3, V31, P70
[4]   ASSAY OF ADENYLATE-CYCLASE BY USE OF POLYACRYLAMIDE-BORONATE GEL COLUMNS [J].
HAGEMAN, JH ;
KUEHN, GD .
ANALYTICAL BIOCHEMISTRY, 1977, 80 (02) :547-554
[5]   ISOLATION OF CATECHOLAMINES IN BIOLOGICAL-FLUIDS BY BORIC-ACID GEL [J].
HIGA, S ;
SUZUKI, T ;
HAYASHI, A ;
TSUGE, I ;
YAMAMURA, Y .
ANALYTICAL BIOCHEMISTRY, 1977, 77 (01) :18-24
[6]   HIGH-PERFORMANCE CHROMATOFOCUSING OF PROTEINS ON AGAROSE COLUMNS .2. DEFORMED NON-POROUS 12-15-MU-M BEADS [J].
HJERTEN, S ;
LI, JP ;
LIAO, JL .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :177-185
[7]   THE DESIGN OF AGAROSE BEDS FOR HIGH-PERFORMANCE HYDROPHOBIC-INTERACTION CHROMATOGRAPHY AND ION-EXCHANGE CHROMATOGRAPHY WHICH SHOW INCREASING RESOLUTION WITH INCREASING FLOW-RATE [J].
HJERTEN, S ;
YAO, KQ ;
LIAO, JL .
MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1988, 17 :349-357
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS ON COMPRESSED, NON-POROUS AGAROSE BEADS .1. HYDROPHOBIC-INTERACTION CHROMATOGRAPHY [J].
HJERTEN, S ;
LIAO, JL .
JOURNAL OF CHROMATOGRAPHY, 1988, 457 :165-174
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS ON DIHYDROXYBORYL-AGAROSE [J].
HJERTEN, S ;
YANG, D .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :301-309
[10]  
HJERTEN S, IN PRESS HPLC PROTEI