INVITRO VALIDATION OF A SIMPLE TOMOGRAPHIC TECHNIQUE FOR ESTIMATION OF PERCENTAGE MYOCARDIUM AT RISK USING METHOXYISOBUTYL ISONITRILE TC-99M (SESTAMIBI)

被引:132
作者
OCONNOR, MK [1 ]
HAMMELL, T [1 ]
GIBBONS, RJ [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DIV CARDIOVASC DIS & INTERNAL MED, ROCHESTER, MN 55905 USA
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1990年 / 17卷 / 1-2期
关键词
Cardiac phantom; Infarct size; SPET;
D O I
10.1007/BF00819407
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the advent of technetium 99m-labeled myocardial blood flow agents, there is a need for a simple technique for quantitation of infarcted or jeopardized myocardium (IM). This study provides an in vitro validation of a simple technique based upon the analysis of three short-axis slices through the heart following emission computed tomography. All acquisitions were performed using a static cardiac phantom containing pertechnetate Tc 99 m. Activity in the phantom was adjusted so that the count density and myocardial-to-background ratio were comparable to those observed in patients. Plastic insets (range of sizes = 4%-72% of myocardium) were used to simulate transmural infarctions. Eighteen studies were acquired, each over 180° into a 64 × 64 matrix. Data were reconstructed using a Ramp Hanning filter with cut off at 0.7 times the Nyquist frequency. Short-axis slices of the myocardium were then generated, and representative apical (A), mid-ventricular (MV), and basal (B) slices were selected. For each slice, a circumferential profile was generated, and the average radius (R) was measured. The fraction (F) of the profile falling below a threshold value was considered to represent IM. Total IM was given by %IM =100 x (RBFB +RMVFMV + 0.67 RAFA)/(RB +RMV + 0.67 RA), where the subscripts to R and F refer to the relevant short-axis slices. For a threshold set at 60% of peak, measured IM agreed closely with true IM (R2=0.98, measured IM =1.01 x true IM -1.35). Measurement of % IM was not distorted by variations in slice radius or in slice selection. Maximum error in % IM occurred with a change in location of the infarct (approximately 4% for opposing walls). This technique permits rapid and accurate assessment of % IM with99mTc-labeled myocardial blood flow agents. © 1990 Springer-Verlag.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 21 条
  • [1] ANGER HO, 1967, INSTRUM NUCL, V1, P485
  • [2] PHYSICS AND INSTRUMENTATION
    BUDINGER, TF
    ROLLO, FD
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) : 19 - 53
  • [3] QUANTITATION OF SIZE OF RELATIVE MYOCARDIAL PERFUSION DEFECT BY SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    CALDWELL, JH
    WILLIAMS, DL
    HARP, GD
    STRATTON, JR
    RITCHIE, JL
    [J]. CIRCULATION, 1984, 70 (06) : 1048 - 1056
  • [4] CORONARY-ARTERY REPERFUSION IN ACUTE MYOCARDIAL-INFARCTION - ASSESSMENT BY PREINTERVENTION AND POSTINTERVENTION TL-201 MYOCARDIAL PERFUSION IMAGING
    DECOSTER, PM
    MELIN, JA
    DETRY, JMR
    BRASSEUR, LA
    BECKERS, C
    COL, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (08) : 889 - 895
  • [5] THE IMPORTANCE OF THE DETERMINATION OF THE MYOCARDIAL AREA AT RISK IN THE EVALUATION OF THE OUTCOME OF ACUTE MYOCARDIAL-INFARCTION IN PATIENTS
    FEIRING, AJ
    JOHNSON, MR
    KIOSCHOS, JM
    KIRCHNER, PT
    MARCUS, ML
    WHITE, CW
    [J]. CIRCULATION, 1987, 75 (05) : 980 - 987
  • [6] FEASIBILITY OF TOMOGRAPHIC TC-99M-HEXAKIS-2-METHOXY-2-METHYLPROPYL-ISONITRILE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL AREA AT RISK AND THE EFFECT OF TREATMENT IN ACUTE MYOCARDIAL-INFARCTION
    GIBBONS, RJ
    VERANI, MS
    BEHRENBECK, T
    PELLIKKA, PA
    OCONNOR, MK
    MAHMARIAN, JJ
    CHESEBRO, JH
    WACKERS, FJ
    [J]. CIRCULATION, 1989, 80 (05) : 1277 - 1286
  • [7] MYOCARDIAL TL-201 KINETICS DURING CORONARY-OCCLUSION AND REPERFUSION - INFLUENCE OF METHOD OF REFLOW AND TIMING OF TL-201 ADMINISTRATION
    GRANATO, JE
    WATSON, DD
    FLANAGAN, TL
    GASCHO, JA
    BELLER, GA
    [J]. CIRCULATION, 1986, 73 (01) : 150 - 160
  • [8] QUANTITATION OF PERFUSED MYOCARDIAL MASS USING T1-201 AND EMISSION COMPUTED-TOMOGRAPHY
    HOLMAN, BL
    MOORE, SC
    SHULKIN, PM
    KIRSCH, CM
    ENGLISH, RJ
    HILL, TC
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : 322 - 326
  • [9] MEASUREMENT OF INFARCT SIZE AND PERCENTAGE MYOCARDIUM INFARCTED IN A DOG PREPARATION WITH SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY, TL-201, AND IN-111 MONOCLONAL ANTIMYOSIN FAB
    JOHNSON, LL
    LERRICK, KS
    COROMILAS, J
    SELDIN, DW
    ESSER, PD
    ZIMMERMAN, JM
    KELLER, AM
    ALDERSON, PO
    BIGGER, JT
    CANNON, PJ
    [J]. CIRCULATION, 1987, 76 (01) : 181 - 190
  • [10] KEYES JW, 1981, J NUCL MED, V22, P339