MEASUREMENT OF AORTIC INPUT IMPEDANCE IN RATS

被引:51
作者
MITCHELL, GF [1 ]
PFEFFER, MA [1 ]
WESTERHOF, N [1 ]
PFEFFER, JM [1 ]
机构
[1] FREE UNIV AMSTERDAM, PHYSIOL LAB, 1081 BT AMSTERDAM, NETHERLANDS
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1994年 / 267卷 / 05期
关键词
CHARACTERISTIC IMPEDANCE; COMPUTER ALGORITHMS; FOURIER ANALYSIS; IMPULSE TRAIN RESPONSE;
D O I
10.1152/ajpheart.1994.267.5.H1907
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of aortic input impedance in the rat is complicated by a high basal heart rate but is possible if appropriate compensation is made for frequency-dependent errors in modulus and phase resulting from analog filters in the equipment and from nonalignment of pressure and flow sensors. Because input impedance is a complex quantity, accurate values for both phase and modulus are required before meaningful interpretation of the data can be made. We measured aortic pressure and electromagnetic ascending aortic blood flow in mature, ether-anesthetized, open-chest male Wistar rats. Pressure and flow waveforms were averaged in the time domain and converted to Fourier series. Flow moduli were corrected for the measured frequency response of the flowmeter. Phase spectra were corrected by the classic frequency-domain and two new time-domain methods. Compensation for instrumentation errors was assessed at two different flowmeter filter settings in five animals. Reproducibility, variability, and the effects of vasoconstriction were assessed in 43 animals. Three methods of estimating characteristic impedance from the impedance spectra were evaluated and found to produce comparable results at baseline and following pharmacological elevation of blood pressure with graded methexamine infusion. Physiologically equivalent values for phase, as assessed by comparing oscillatory power calculated from the impedance spectra, were obtained with each of the phase-correction techniques. The new time-domain methods facilitate the assessment of aortic input impedance in this small animal model because they do not require measurement of the spatial separation between pressure and flow transducers and pulse wave velocity in the proximal aorta.
引用
收藏
页码:H1907 / H1915
页数:9
相关论文
共 20 条
[1]  
BRAS YL, 1986, MED BIOL ENG COMPUT, V24, P329
[2]  
BRIGHAM EO, 1988, FAST FOURIER TRANSFO, P167
[3]   DETERMINANTS OF SYSTEMIC HYDRAULIC POWER IN UNANESTHETIZED DOGS [J].
COX, RH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1974, 226 (03) :579-587
[4]   EFFECTS OF AGE ON MECHANICAL-PROPERTIES OF RAT CAROTID-ARTERY [J].
COX, RH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (02) :H256-H263
[5]   CRITERIA FOR OPTIMAL AVERAGING OF CARDIAC SIGNALS [J].
CRAELIUS, W ;
RESTIVO, M ;
ASSADI, MA ;
ELSHERIF, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (10) :957-966
[6]   FREQUENCY RESPONSE OF ELECTROMAGNETIC FLOWMETERS [J].
GESSNER, U ;
BERGEL, DH .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (06) :1209-+
[7]  
Latson T. W., 1987, VENTRICULAR VASCULAR, P334
[8]   CHARACTERIZATION OF ARTERIAL SYSTEM IN TIME DOMAIN [J].
LAXMINARAYAN, S ;
SIPKEMA, P ;
WESTERHOF, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1978, 25 (02) :177-184
[9]  
MILNOR WR, 1989, HEMODYNAMICS, P183
[10]  
MITCHELL GF, 1991, HYPERTENSION, V18, P417