COMPARISON OF THE UTILITY OF CT SCANS AND INTRAVASCULAR ULTRASOUND IN ENDOVASCULAR AORTIC GRAFTING

被引:34
作者
VERBIN, C [1 ]
SCOCCIANTI, M [1 ]
KOPCHOK, G [1 ]
DONAYRE, C [1 ]
WHITE, RA [1 ]
机构
[1] UNIV CALIF LOS ANGELES,HARBOR MED CTR,DEPT VASC SURG,TORRANCE,CA 90509
关键词
D O I
10.1007/BF02143856
中图分类号
R61 [外科手术学];
学科分类号
摘要
Using CT scans and intravascular ultrasound (IVUS), aortic, aneurysm neck, and endoluminal graft cross-sectional dimensions were compared in a canine model before and after placement of endoluminal grafts in normal aortas (n = 10) and in artificially constructed abdominal aortic aneurysms (n = 15). Measurement of diameters (n = 83) revealed an average difference or bias between imaging modalities of 0.17 +/- 0.92 mm. Measurements obtained using IVUS were slightly larger than CT values (8.84 +/- 1.0 vs. 8.65 +/- 1.1, p <0.03) but correlated very well by linear regression analysis (r = 0.948, p <0.02). Analysis of cross-sectional area (n = 44) revealed an average difference or bias of 7.21 +/- 7.76 mm(2) between the two modalities. Again IVUS measurements were larger than CT measurements (65.0 +/- 16.5 vs. 57.9 +/- 11.9, p <0.001) and linear regression analysis showed less correlation (r = 0.897, p <0.001). Qualitative assessment of the graft and stent characteristics was more precise using IVUS. Graft folding, stent-aorta interfaces, and thrombus formation were easily identified by IVUS, whereas these more subtle characteristics were missed by CT scanning and arteriography. These studies demonstrate that IVUS measurements were slightly larger than CT values; however, both modalities demonstrate small bias and good correlation. Qualitative analysis of the aneurysmal aorta and endoluminal graft using IVUS is comparable to and in some respects more detailed than measurements from CT scanning and arteriography.
引用
收藏
页码:434 / 440
页数:7
相关论文
共 13 条
[1]   TRANS-FEMORAL PLACEMENT OF INTRALUMINAL POLYURETHANE PROSTHESIS FOR ABDOMINAL AORTIC-ANEURYSM [J].
BALKO, A ;
PIASECKI, GJ ;
SHAH, DM ;
CARNEY, WI ;
HOPKINS, RW ;
JACKSON, BT .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) :305-309
[2]  
CAVAYE DM, 1993, INT ANGIOL, V12, P212
[3]   TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
FIORE, WM ;
DEWEESE, JA ;
QUERAL, LA ;
CRIADO ;
NATH, RL ;
BERKOWITZ, HD ;
SUMPIO, BE .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :185-197
[4]  
COLOMBO A, 1994, 7TH INT C END INT SC
[5]  
GOLDBERG SL, 1993, CIRCULATION, V88, P597
[6]  
KATZEN BT, 1991, CIRCULATION S2, V84, P2152
[7]   INTRAVASCULAR ULTRASOUND ASSESSMENT OF LUMEN SIZE AND WALL MORPHOLOGY IN NORMAL SUBJECTS AND PATIENTS WITH CORONARY-ARTERY DISEASE [J].
NISSEN, SE ;
GURLEY, JC ;
GRINES, CL ;
BOOTH, DC ;
MCCLURE, R ;
BERK, M ;
FISCHER, C ;
DEMARIA, AN .
CIRCULATION, 1991, 84 (03) :1087-1099
[8]  
PARODI J, 1993, ADV VASCULAR SURGERY, P85
[9]  
Parodi J C, 1991, Ann Vasc Surg, V5, P491, DOI 10.1007/BF02015271
[10]   INVIVO HUMAN COMPARISON OF INTRAVASCULAR ULTRASONOGRAPHY AND ANGIOGRAPHY [J].
TABBARA, M ;
WHITE, R ;
CAVAYE, D ;
KOPCHOK, G .
JOURNAL OF VASCULAR SURGERY, 1991, 14 (04) :496-504