COMPARISON OF MYOCARDIAL PERFUSION IMAGING WITH TC-99M TETROFOSMIN VERSUS TL-201 IN CORONARY-ARTERY DISEASE

被引:83
作者
SRIDHARA, BS
BRAAT, S
RIGO, P
ITTI, R
CLOAD, P
LAHIRI, A
RAVAL, U
FOULON, J
机构
[1] ACAD HOSP MAASTRICHT,DEPT CARDIOL,P DEBEYELAAN 25,POB 5800,6202 AZ MAASTRICHT,NETHERLANDS
[2] CLIN RES CTR,HARROW HA1 3UJ,MIDDX,ENGLAND
[3] AMERSHAM INT PLC,AMERSHAM,ENGLAND
[4] NORTHWICK PK HOSP & CLIN RES CTR,HARROW HA1 3UJ,MIDDX,ENGLAND
[5] CHU LIEGE,LIEGE,BELGIUM
[6] HOSP NEUROCARDIOL,LYON,FRANCE
关键词
D O I
10.1016/0002-9149(93)90855-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Technetium-99m (Tc-99m) tetrofosmin, a new myocardial perfusion imaging agent, was evaluated at exercise and rest in 50 patients with documented coronary artery disease to determine myocardial kinetics, redistribution and ideal imaging time. Planar imaging was performed at 5, 30 60, 90, 120 and 240 minutes after an injection of Tc-99m tetrofosmin (8 to 10 mCi) at peak graded ergometric exercise. Reinjection (24 to 30 mCi) was performed at rest, 4 hours after the stress injection and also on a separate day, and imaging was repeated. All patients underwent thallium-201 (Tl-201) exercise and redistribution (4-hour) imaging. Perfusion defect to normal, and heart to lung ratios were calculated for exercise Tc-99m tetrofosmin images at each time point. The mean +/- SD defect to normal ratios were 0.75 +/- 0.10, 0.75 +/- 0.10, 0.74 +/- 0.09, 0.73 +/- 0.10, 0.73 +/- 0.10 and 0.72 +/- 0.10 at 5, 30, 60, 90, 120 and 240 minutes, respectively (p = NS), suggesting absence of redistribution. There was a significant increase in lung uptake of Tl-201 during exercise (p < 0.05), but not with Tc-99m tetrofosmin (p = NS). Washout of Tc-99m tetrofosmin was calculated in a subset of patients (n = 23). Rapid background clearance enabled postexercise diagnostic imaging as early as 5 minutes after injection. Myocardial retention curves after rest injection suggested that the optimal time for imaging was approximately 30 minutes later. Slow myocardial washout (4%/hour after exercise and 0.6%/hour after rest injection) enabled diagnostic images to be obtained up to 4 hours after each study. Image quality was generally superior to that with Tl-201. Tc-99m tetrofosmin has the advantage of early imaging after exercise, with no evidence of redistribution.
引用
收藏
页码:1015 / 1019
页数:5
相关论文
共 27 条
  • [1] INTRODUCTION - TC-99M MYOCARDIAL PERFUSION IMAGING AGENTS AND THEIR RELATION TO TL-201
    BERMAN, DS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) : E1 - E4
  • [2] BERMAN DS, 1991, CIRCULATION S1, V84, P7
  • [3] PROGNOSTIC VALUE OF EXERCISE TL-201 IMAGING IN PATIENTS PRESENTING FOR EVALUATION OF CHEST PAIN
    BROWN, KA
    BOUCHER, CA
    OKADA, RD
    GUINEY, TE
    NEWELL, JB
    STRAUSS, HW
    POHOST, GM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (04) : 994 - 1001
  • [4] PREDICTION OF CARDIAC EVENTS AFTER UNCOMPLICATED MYOCARDIAL-INFARCTION - A PROSPECTIVE-STUDY COMPARING PREDISCHARGE EXERCISE TL-201 SCINTIGRAPHY AND CORONARY ANGIOGRAPHY
    GIBSON, RS
    WATSON, DD
    CRADDOCK, GB
    CRAMPTON, RS
    KAISER, DL
    DENNY, MJ
    BELLER, GA
    [J]. CIRCULATION, 1983, 68 (02) : 321 - 336
  • [5] TIME TO COMPLETED REDISTRIBUTION OF TL-201 IN EXERCISE MYOCARDIAL SCINTIGRAPHY - RELATIONSHIP TO THE DEGREE OF CORONARY-ARTERY STENOSIS
    GUTMAN, J
    BERMAN, DS
    FREEMAN, M
    ROZANSKI, A
    MADDAHI, J
    WAXMAN, A
    SWAN, HJC
    [J]. AMERICAN HEART JOURNAL, 1983, 106 (05) : 989 - 995
  • [6] HIGLEY B, 1993, J NUCL MED, V34, P30
  • [7] HIGLEY B, 1992, WHATS NEW CARDIAC IM
  • [8] HOLMAN BL, 1984, J NUCL MED, V25, P1350
  • [9] MYOCARDIAL IMAGING WITH TC-99M TEBOROXIME - TECHNIQUE AND INITIAL RESULTS
    ISKANDRIAN, AS
    HEO, J
    NGUYEN, T
    MERCURO, J
    [J]. AMERICAN HEART JOURNAL, 1991, 121 (03) : 889 - 894
  • [10] ISKANDRIAN AS, 1991, J NUCL MED, V32, P1966