EVALUATION OF A HOT-WIRE RESPIRATORY FLOWMETER FOR CLINICAL APPLICABILITY

被引:28
作者
YOSHIYA, I
SHIMADA, Y
TANAKA, K
机构
关键词
D O I
10.1152/jappl.1979.47.5.1131
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A hot-wire flowmeter was evaluated for clinical applicability. Calibration with a syringe could be done if emptying duration was 1-15 s. Outputs linearly decreased with decreasing concentration of N2 in O2. Outputs with CO2 in O2 and N2O in O2 represented nonlinear convex relationships with varying concentrations of CO2 and N2O. Correction for each gas mixture to be measured is required. Outputs linearly decreased with decreasing barometric pressure. Stability assessed with a piston respirator was excellent (within ±2% of syringe volume) after 15 min warmup time. However, daily calibrations are recommended in clinical situations. Nebulization, if not excessive, was acceptable if the expired gas was measured at the mouth. Hot-wire burning, which occurred when it was partially in contact with materials whose specific heat differed with air, was successfully protected with a simple shutoff circuit. The possibility of producing nitrogen oxides by the catalytic action of the platinum hot-wire was denied by colorimetric determination. Interchangeability and sterilizability of transducers and improved mechanical strength with platinum-rhodium alloy are also discussed.
引用
收藏
页码:1131 / 1135
页数:5
相关论文
共 9 条
[1]   EVALUATION OF ELECTRONIC SPIROMETERS [J].
FITZGERALD, MX ;
SMITH, AA ;
GAENSLER, EA .
NEW ENGLAND JOURNAL OF MEDICINE, 1973, 289 (24) :1283-1288
[2]   APPLICATION OF HOT-WIRE ANEMOMETER TO RESPIRATORY MEASUREMENTS IN SMALL ANIMALS [J].
GODAL, A ;
BELENKY, DA ;
STANDAERT, TA ;
WOODRUM, DE ;
GRIMSRUD, L ;
HODSON, WA .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (02) :275-277
[3]  
HIRSCHFELDER JO, 1967, MOL THEORY GASES LIQ, P514
[4]  
JANSSEN JML, 1959, P IRE, V47, P555
[5]  
LADENBURG RW, 1954, PHYSICAL MEASUREMENT, P219
[6]   THERMAL CONDUCTIVITY OF GAS MIXTURES [J].
LINDSAY, AL ;
BROMLEY, LA .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1950, 42 (08) :1508-1511
[7]   COLORIMETRIC MICRODETERMINATION OF NITROGEN DIOXIDE IN THE ATMOSPHERE [J].
SALTZMAN, BE .
ANALYTICAL CHEMISTRY, 1954, 26 (12) :1949-1955
[8]   MODIFIED NITROGEN DIOXIDE REAGENT FOR RECORDING AIR ANALYZERS [J].
SALTZMAN, BE .
ANALYTICAL CHEMISTRY, 1960, 32 (01) :135-136
[9]   BIDIRECTIONAL RESPIRATORY FLOWMETER USING HOT-WIRE PRINCIPLE [J].
YOSHIYA, I ;
NAKAJIMA, T ;
NAGAI, I ;
JITSUKAWA, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (02) :360-365