STUDIES OF THE PH OF THE MEMBRANE-SURFACE IN A LABORATORY CHLORALKALI CELL

被引:9
作者
OGATA, Y [1 ]
UCHIYAMA, S [1 ]
HAYASHI, M [1 ]
YASUDA, M [1 ]
HINE, F [1 ]
机构
[1] NAGOYA INST TECHNOL,DEPT APPL CHEM,NAGOYA,AICHI 466,JAPAN
关键词
D O I
10.1007/BF01008863
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The pH on the surface of an ion-exchange membrane was measured with a microprobe in a laboratory scale chlor-alkali cell to study the leakage of OH- through the membrane. The solution pH in the vicinity of the membrane facing the anode was found to be considerably higher than that in the bulk solution because of penetration and leakage of OH-. The pH varied with the membrane type. This explains why the carboxylate membrane is not protonated and can be used as a separator in chlor-alkali cells. © 1990 Chapman and Hall Ltd.
引用
收藏
页码:555 / 558
页数:4
相关论文
共 9 条
[1]  
CHANDRAN RR, 1985, EECTROCHIM ACTA, V30, P158
[2]  
GROT WGF, 1972, MAY EL SOC M HOUST
[3]  
HEITZ E, 1986, PRINCIPLES ELECTROCH, P197
[4]  
IVES DJG, 1961, REFERENCE ELECTRODES, pCH7
[5]  
OAGATA Y, 1989, J ELECTROCHEM SOC, V136, P91
[6]  
RODININI S, 1986, P S DIAPHRAGMS SEPAR, P120
[7]   A COMPARISON OF PERFLUORINATED CARBOXYLATE AND SULFONATE ION-EXCHANGE POLYMERS .2. SORPTION AND TRANSPORT-PROPERTIES IN CONCENTRATED-SOLUTION ENVIRONMENTS [J].
TWARDOWSKI, Z ;
YEAGER, HL ;
ODELL, B .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (02) :328-332
[8]  
WALTON CW, 1987, OCT EL SOC M HON
[9]  
YEO RS, 1985, MODERN ASPECTS ELECT, V16, pCH6