PULSEWAVE VELOCITY-MEASUREMENT USING A NEW REAL-TIME MR-METHOD

被引:33
作者
BOCK, M
SCHAD, LR
MULLER, E
LORENZ, WJ
机构
[1] Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum (dkfz), Heidelberg
[2] Siemens Medical Division, Erlangen
关键词
MAGNETIC RESONANCE IMAGING; PULSEWAVE MEASUREMENTS; FLOW QUANTIFICATION; REAL TIME ACQUISITION IN 1-DIMENSIONAL PROJECTION (RACE); STATIONARY TISSUE SUPPRESSION;
D O I
10.1016/0730-725X(94)00077-G
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new, one-dimensional method for the measurement of pulsewave velocities using real-time magnetic resonance (MR) imaging is presented. The measurement sequence is essentially of a RACE-type (Real Time Acquisition and Evaluation) with interleaved acquisition in two not necessarily parallel slices. In each slice the blood flow velocity perpendicular to the slice orientation was monitored. From the relative time difference of blood flow activity and the slice distance, pulsewave velocities were calculated. With a time resolution of 13 ms an overall acquisition time of 3.3 s was achieved. A method for suppression of signal contributions from stationary tissue along the axis of projection is discussed on the basis of a simplified mathematical model. Preliminary volunteer studies show that pulsewave velocities in the range of 1-10 m/s can be measured with an uncertainty of about 0.6 m/s at a conventional 1.5 T imager with a gradient system of maximal 10 mT/m.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 10 条
[1]  
Keller, Wilke, Blumenstein, Raue, Konventionelle Röntgen-Funktionsdiagnostik-Videometrie, Z. ges. Inn. Med., 47, pp. 480-483, (1992)
[2]  
Hoyndu, Bergey, Leigh, Flow-induced adiabatic fast passage bolus tagging for estimation of vascular compliance, Book of abstracts: Twelfth Annual Meeting of the Society of Magnetic Resonance in Medicine, (1993)
[3]  
Bohning, Wood, Peters, Shivji, Multislice flow quantification provides reproducible measurement of aortic compliance, Book of abstracts: Twelfth Annual Meeting of the Society of Magnetic Resonance in Medicine, (1993)
[4]  
Dumoulin, Doorly, Caro, Quantitative measurement of velocity at multiple positions using comb excitation and Fourier velocity encoding, Magn. Reson. Med., 29, pp. 44-52, (1993)
[5]  
Muller, Laub, Graumann, Loeffler, RACE-Real time acquisition and evaluation of pulsatile blood flow on a whole body MRI unit, Book of abstracts: Seventh Annual Meeting of the Society of Magnetic Resonance in medicine, (1988)
[6]  
Wacker, Schad, Gehling, Gamroth, Muller, Knopp, Schulz, van Kaick, The pulmonary artery acceleration time determined with the MR-RACE-technique: Comparison to pulmonary artery mean pressure in 12 patients, Magn. Reson. Imaging, 12, 1, pp. 25-31, (1994)
[7]  
Gullberg, Simons, Wehrli, A mathematical model for signal from spins flowing during the application of spin echo pulse sequences, Magn. Reson. Imaging, 6, pp. 437-461, (1988)
[8]  
Ernst, Anderson, Application of Fourier transform spectroscopy to magnetic resonance, Rev. Sci. Instr., 37, 1, pp. 93-102, (1966)
[9]  
Busse, Bauer, Arteriensystem, Kreislaufphysiologie, pp. 60-62, (1982)
[10]  
Urchuk, Chevrier, Plewes, A three-point method for measurement of pulse wave velocity with MR, Book of abstracts: Twelfth Annual Meeting of the Society of Magnetic Resonance in Medicine, (1993)