SIMULTANEOUS MEASUREMENT OF QUININE AND QUINIDINE IN HUMAN PLASMA, WHOLE-BLOOD, AND ERYTHROCYTES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:28
作者
EDSTEIN, MD [1 ]
PRASITTHIPAYONG, A [1 ]
SABCHAREON, A [1 ]
CHONGSUPHAJAISIDDHI, T [1 ]
WEBSTER, HK [1 ]
机构
[1] MAHIDOL UNIV,HOSP TROP DIS,FAC TROP MED,DEPT TROP PEDIAT,BANGKOK 10700,THAILAND
关键词
High-performance liquid chromatography; Malaria; Quinidine; Quinine;
D O I
10.1097/00007691-199009000-00015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A high-performance liquid chromatographic method with fluorescence detection is described for the simultaneous measurement of quinine and quinidine in plasma, whole blood, and erythrocytes. The compounds were separated on an Ultrasphere C18 reversed-phase column (25 cm x 4.6 mm inside diameter, 5 μm particle size) using a mobile phase of acetonitrile/water/triethylamine (11:88:1, vol/vol) at pH 2.5. The method, simple, accurate, and selective, requires only a single-step liquid-liquid extraction and uses the structurally similar alkaloid, cinchonine, as the internal standard. The commercial impurities, dihydroquinine and dihydroquinidine, and unknown metabolites were well resolved from the parent drugs. The assay is precise, with interassay coefficients of variation 7.0% and an accuracy of 7.3% over a concentration range of 0.125 to 4.0 μg/0.25 ml. The extraction recoveries of the two drugs were similar, averaging 82.9% for quinine and 79.3% for quinidine from the three biological fluids. The clinical application of the method for routine drug monitoring and for estimating the pharmacokinetics of quinine and quinidine in man are discussed. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 21 条
  • [1] BRODIE BB, 1951, J BIOL CHEM, V188, P567
  • [2] QUANTITATIVE DETERMINATION OF QUINIDINE IN PLASMA
    CRAMER, G
    ISAKSSON, B
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1963, 15 (05) : 553 - &
  • [3] DRAYER DE, 1977, J LAB CLIN MED, V90, P816
  • [4] QUANTIFICATION OF QUININE IN HUMAN-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    EDSTEIN, M
    STACE, J
    SHANN, F
    [J]. JOURNAL OF CHROMATOGRAPHY, 1983, 278 (02): : 445 - 451
  • [5] DETERMINATION OF QUINIDINE AND ITS MAJOR METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GUENTERT, TW
    COATES, PE
    UPTON, RA
    COMBS, DL
    RIEGELMAN, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 162 (01): : 59 - 70
  • [6] JAMALUDIN A, 1988, Acta Leidensia, V57, P39
  • [7] KARBWANG J, 1989, Southeast Asian Journal of Tropical Medicine and Public Health, V20, P65
  • [8] FATAL PLASMODIUM-FALCIPARUM MALARIA AFTER AN INADEQUATE RESPONSE TO QUININE TREATMENT
    LOOAREESUWAN, S
    CHAROENPAN, P
    HO, M
    WHITE, NJ
    KARBWANG, J
    BUNNAG, D
    HARINASUTA, T
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1990, 161 (03) : 577 - 580
  • [9] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF QUININE AND ITS DIASTEREOISOMER QUINIDINE
    MIHALY, GW
    HYMAN, KM
    SMALLWOOD, RA
    HARDY, KJ
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 415 (01): : 177 - 182
  • [10] INTRAVENOUS QUINIDINE FOR THE TREATMENT OF SEVERE FALCIPARUM-MALARIA - CLINICAL AND PHARMACOKINETIC STUDIES
    PHILLIPS, RE
    WARRELL, DA
    WHITE, NJ
    LOOAREESUWAN, S
    KARBWANG, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1985, 312 (20) : 1273 - 1278