DIODE-ARRAY DETECTION AND SIMULTANEOUS QUANTITATION OF THE COELUTING ATENOLOL-RELATED SYNTHETIC ROUTE IMPURITIES, PPA-DIOL

被引:7
作者
OWINO, E
CLARK, BJ
FELL, AF
机构
[1] Department of Pharmaceutical Chemistry, School of Pharmacy, University of Bradford, Bradford
关键词
D O I
10.1093/chromsci/29.10.450
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The diode array multichannel detector is used to acquire spectral information at specified intervals in the elution profile of atenolol and its related impurities for post-chromatographic data analysis. The applicability of a number of peak homogeneity testing methods, including spectral normalization, absorbance ratio, chromatographic derivatives, and spectral suppression (SS), are assessed for suitability in simultaneous determinations of the coeluting atenolol-related synthetic impurities, PPA-Diol. Spectral suppression displays a superior performance in comparison to all the other techniques in that both qualitative and quantitative information are acquired on the system.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 19 条
[1]   LIQUID-CHROMATOGRAPHIC RETENTION OF BETA-ADRENOCEPTOR ANTAGONISTS - AN INDEX OF LIPID SOLUBILITY [J].
ARENDT, RM ;
GREENBLATT, DJ .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1984, 36 (06) :400-401
[2]   PEAK HOMOGENEITY DETERMINATION FOR THE VALIDATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY-METHODS [J].
CARTER, GT ;
SCHIESSWOHL, RE ;
BURKE, H ;
YANG, R .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1982, 71 (03) :317-321
[3]   DIGITAL-TECHNIQUES FOR LUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY WITH AN INTENSIFIED LINEAR PHOTODIODE ARRAY [J].
CLARK, BJ ;
FELL, AF ;
JONES, DG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (6-8) :843-852
[4]  
DAY N H, 1984, Analytical Proceedings, V21, P235, DOI 10.1039/ap9842100235
[5]  
FASANMADE AA, 1985, THESIS
[6]   NOVEL TECHNIQUES FOR PEAK RECOGNITION AND DECONVOLUTION BY COMPUTER-AIDED PHOTODIODE ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :123-140
[7]   SIMPLE AND RAPID ANALYSIS OF ATENOLOL AND METOPROLOL IN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARRISON, PM ;
TONKIN, AM ;
MCLEAN, AJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 339 (02) :429-433
[8]   PEAK BROADENING IN ION-PAIR LIQUID-CHROMATOGRAPHY OF SUBSTITUTED PHENOXYPROPANOLAMINES ON DYNAMICALLY MODIFIED SILICA [J].
JANSSON, SO ;
JOHANSSON, ML .
JOURNAL OF CHROMATOGRAPHY, 1987, 395 :495-501
[9]   SIMPLE EXTRACTION OF ATENOLOL FROM URINE AND ITS DETERMINATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KEECH, AC ;
HARRISON, PM ;
MCLEAN, AJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 426 (01) :234-236
[10]  
MARR JGD, 1988, THESIS, P93