EFFECT OF MICROPORE STRUCTURE ON AUTOCLAVED AERATED CONCRETE SHRINKAGE

被引:34
作者
GEORGIADES, A [1 ]
FTIKOS, C [1 ]
MARINOS, J [1 ]
机构
[1] HERACLES GEN CEMENT CO,HELLEN CEMENT RES CTR,GR-14123 ATHENS,GREECE
关键词
D O I
10.1016/0008-8846(91)90116-Y
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Autoclaved Aerated Concrete (A.A.C.) specimens were prepared using various raw materials, additives, rising agents and autoclaving conditions. In these specimens, drying shrinkage was measured, as well as micropore volume and specific surface distribution were determined by means of mercury porosimetry. It is concluded that A.A.C. drying shrinkage is a function of volume and specific surface of the micropores which have radii between 20 and 200 angstrom. Relationships based on statistical analysis of micropore structure have been proposed to ensure the shrinkage characteristics of the A.A.C.
引用
收藏
页码:655 / 662
页数:8
相关论文
共 4 条
[1]  
ALEXANDERSON J, 1977, CEMENT CONCRETE RES, V7, P323
[2]  
HOUST Y, 1983, P AUT AER CONCR MOIS, P219
[3]  
PRIM P, 1983, P RILEM INT S AUT AE, P55
[4]  
1981, BS6073 BRIT STAND 1, V1