A FAST READOUT SYSTEM FOR 2D GAS-FILLED DETECTORS BASED ON THE DELAY-LINE METHOD

被引:7
作者
BERRY, A
GABRIEL, A
KOCSIS, M
RIEKEL, C
机构
[1] EUROPEAN SYNCHROTRON RES FACIL,BP 220,F-38043 GRENOBLE,FRANCE
[2] ILL GRENOBLE,EUROPEAN MOLEC BIOL LAB,F-38042 GRENOBLE,FRANCE
关键词
D O I
10.1016/0168-9002(94)90757-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new generation of high brilliance synchrotron radiation sources such as the ESRF requires detectors with improved counting rate capability and resolution. Gas filled detectors are of particular interest for small-angle scattering applications due to their low inherent background. A counting rate increase of delay-line based 2D detectors is possible through the reduction of the delay line and a modularisation of the detector. To this end a new readout system has been designed based on VME/VXI modules. The heart of the system is a Time-to-Digital Converter (TDC) with 50 ps resolution (at 200 MHz master clock frequency). Counting rates in excess of 1.8 MHz have been demonstrated with a 100 x 100 mm2 detector and 20 ns delay line. A further improvement of the TDC should allow counting rates up to 5 MHz.
引用
收藏
页码:334 / 337
页数:4
相关论文
共 15 条
[1]   A VME BASED DATA ACQUISITION-SYSTEM FOR A 2D-GASFILLED DETECTOR [J].
BARBOSA, AF ;
BOULIN, C ;
GABRIEL, A ;
GOLDING, F ;
LEYENDECKER, P ;
RIEKEL, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (03) :489-492
[2]   DUAL TIME TO DIGITAL CONVERTER FOR DELAY-LINE READOUT OF POSITION-SENSITIVE GAS-FILLED DETECTORS [J].
BERRY, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05) :1222-1228
[3]   HIGH-RESOLUTION X-RAY GAS PROPORTIONAL DETECTORS WITH DELAY-LINE POSITION SENSING FOR HIGH COUNTING RATES [J].
BOIE, RA ;
FISCHER, J ;
INAGAKI, Y ;
MERRITT, FC ;
RADEKA, V ;
ROGERS, LC ;
XI, DM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01) :93-115
[4]   NEW TYPE OF POSITION-SENSITIVE DETECTORS OF IONIZING RADIATION USING RISETIME MEASUREMENT [J].
BORKOWSKI, CJ ;
KOPP, MK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (10) :1515-+
[5]  
BOSECKE P, 1992, REV SCI INSTRUM, V63, P438, DOI 10.1063/1.1142724
[6]   DATA ACQUISITION-SYSTEMS FOR LINEAR AND AREA X-RAY-DETECTORS USING DELAY-LINE READOUT [J].
BOULIN, CJ ;
KEMPF, R ;
GABRIEL, A ;
KOCH, MHJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01) :312-320
[7]   TRANSMISSION-LINE CONNECTIONS BETWEEN DETECTOR AND FRONT-END ELECTRONICS IN LIQUID ARGON CALORIMETRY [J].
CHASE, RL ;
DELATAILLE, C ;
RESCIA, S ;
SEGUIN, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :228-242
[8]   POSITION SENSITIVE PROPORTIONAL DETECTOR FOR X-RAY CRYSTALLOGRAPHY [J].
GABRIEL, A ;
DUPONT, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (11) :1600-&
[9]   THE LOCALIZATION METHOD USED AT EMBL [J].
GABRIEL, A ;
DAUVERGNE, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01) :223-224
[10]   DOUBLE FOCUSING X-RAY-CAMERA FOR USE WITH SYNCHROTRON RADIATION [J].
HENDRIX, J ;
KOCH, MHJ ;
BORDAS, J .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1979, 12 (OCT) :467-472