THE EFFICACY OF POLYMERIZED PYRIDOXYLATED HEMOGLOBIN SOLUTION AS AN O-2 CARRIER

被引:36
作者
GOULD, SA [1 ]
SEHGAL, LR [1 ]
ROSEN, AL [1 ]
SEHGAL, HL [1 ]
MOSS, GS [1 ]
机构
[1] UNIV CHICAGO,PRITZKER SCH MED,CHICAGO,IL 60637
关键词
D O I
10.1097/00000658-199004000-00003
中图分类号
R61 [外科手术学];
学科分类号
摘要
A polymerized pyridoxylated hemoglobin solution (Poly SFHP) has been prepared with a normal [Hb] of 14 g/dL, a normal COP of 20 to 25 torr, a P50 of 16 to 20 torr, and a plasma T1/2 of 40 to 46 hours. Animals underwent a total exchange transfusion with Poly SFH-P to assess its ability to support hemodynamics and oxygen transport in the absence of red cells. All animals survived the exchange transfusion. Mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), and oxygen consumption (V̊O2) remained at baseline values at zero hematocrit after the exchange. The final plasma [Hb] at Hct less than 1% was 9.7 ± 0.4 g/dL. These results are significantly better than previous data with unmodified tetrameric hemoglobin solution (SFH). Poly SFH-P supports life in the absence of red cells. In contrast to SFH, Poly SFH-P achieves a nearly normal [Hb], a longer T1/2, and maintains baseline hemodynamics and oxygen consumption at zero hematocrit. These results document that Poly SFH-P is an effective oxygen carrier that offers greater potential than previous products as a clinically useful red cell substitute.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 12 条
  • [1] GOULD SA, 1985, SURG FORUM, V36, P30
  • [2] HEMOGLOBIN SOLUTION - IS A NORMAL [HB] OR P50 MORE IMPORTANT
    GOULD, SA
    SEHGAL, LR
    ROSEN, AL
    SEHGAL, HL
    LEVINE, HD
    RICE, CL
    MOSS, GS
    [J]. JOURNAL OF SURGICAL RESEARCH, 1982, 33 (03) : 189 - 193
  • [3] THE EFFECT OF ALTERED HEMOGLOBIN-OXYGEN AFFINITY ON OXYGEN-TRANSPORT BY HEMOGLOBIN SOLUTION
    GOULD, SA
    ROSEN, A
    SEHGAL, L
    NOUD, G
    SEHGAL, H
    DEWOSKIN, R
    LEVINE, H
    KERSTEIN, M
    RICE, C
    MOSS, GS
    [J]. JOURNAL OF SURGICAL RESEARCH, 1980, 28 (03) : 246 - 251
  • [4] POLYMERIZED PYRIDOXYLATED HEMOGLOBIN - EFFICACY AS AN O-2 CARRIER
    GOULD, SA
    ROSEN, AL
    SEHGAL, LR
    SEHGAL, HL
    MOSS, GS
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1986, 26 (10) : 903 - 908
  • [5] KAPLAN HR, 1975, FED PROC, V34, P1461
  • [6] MESSMER K, 1977, BIBL ANAT, V15, P375
  • [7] MOSS GS, 1984, SURGERY, V95, P249
  • [8] MOSS GS, 1976, SURG GYNECOL OBSTET, V142, P357
  • [9] METHODOLOGY TO ASSESS THE OXYGEN CONCENTRATION OF RED-CELLS AND STROMA-FREE HEMOGLOBIN-SOLUTIONS
    ROSEN, AL
    SEHGAL, LR
    GOULD, SA
    SEHGAL, HL
    MOSS, GS
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (02) : 147 - 150
  • [10] SEHGAL HL, 1980, CLIN CHEM, V26, P362