DIASTOLIC CIRCULATORY DYNAMICS IN THE PRESENCE OF ELEVATED PLACENTAL RESISTANCE AND RETROGRADE DIASTOLIC FLOW IN THE UMBILICAL ARTERY - A DOPPLER ECHOGRAPHIC STUDY IN LAMBS

被引:37
作者
FOURON, JC
TEYSSIER, G
MAROTO, E
LESSARD, M
MARQUETTE, G
机构
[1] UNIV MONTREAL,HOP ST JUSTINE,DEPT PEDIAT,DIV PEDIAT CARDIOL,FETAL CARDIOL UNIT,MONTREAL H3T 1C5,QUEBEC,CANADA
[2] UNIV MONTREAL,HOP ST JUSTINE,DEPT OBSTET & GYNECOL,MONTREAL H3T 1C5,QUEBEC,CANADA
基金
英国医学研究理事会;
关键词
FETUS; DOPPLER ULTRASONOGRAPHY; UMBILICAL CIRCULATION;
D O I
10.1016/0002-9378(91)90653-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To evaluate the effects of elevated placental resistance on the diastolic blood flow in the main arteries of the fetus, placental resistance was mechanically increased in six exteriorized lambs. A string was inserted into the exposed section of the umbilical cord and around the veins isolating them from the arteries. Doppler flow velocities waveforms were measured by placing a lightweight acoustic bag on the umbilical cord. Placental resistance was increased by tightening the string until retrograde diastolic flow was observed in the umbilical artery. All measurements were obtained within 10 minutes. Heart rate, Po2, Pco2, and pH before umbilical vein compression were 177 +/- 24 beats/min, 16.4 +/- 1.8 mm Hg, 42.5 +/- 4 mm Hg, and 7.3 +/- 0.05, respectively, and 112 +/- 38 beats/min, 5.9 +/- 1.5 mm Hg, 56.6 +/- 7.0 mm Hg, and 7.2 +/- 0.05, respectively, after umbilical vein compression. The patterns of diastolic flow observed after compression were descending aorta, retrograde; aortic arch, retrograde; ascending aorta, bidirectional; cephalic aorta, forward, which were quite different from their respective baseline patterns. It is concluded that the appearance of reverse diastolic flow in the umbilical artery indicates that (1) the lowest vascular resistance in the fetal circulatory network is no longer at the placental but at the cerebral level, and (2) preplacental blood with low oxygen content from the descending aorta and pulmonary artery is being shifted toward the brain.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 14 条
[1]   EXPLORATION OF THE FETAL CEREBRAL BLOOD-FLOW BY DUPLEX DOPPLER LINEAR-ARRAY SYSTEM IN NORMAL AND PATHOLOGICAL PREGNANCIES [J].
ARBEILLE, P ;
RONCIN, A ;
BERSON, M ;
PATAT, F ;
POURCELOT, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (06) :329-337
[2]   CHANGES IN THE SYSTOLIC-TIME INTERVALS OF THE FETAL HEART AFTER SURGICAL MANIPULATION OF THE FETUS [J].
DEMUYLDER, X ;
FOURON, JC ;
BARD, H ;
URFER, FN .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1983, 147 (03) :285-288
[3]  
Gosling R., 1975, ARTERIES VEINS, P61
[4]   DOPPLER BLOOD-FLOW WAVEFORMS IN THE DESCENDING THORACIC AORTA OF THE HUMAN-FETUS [J].
GRIFFIN, D ;
BILARDO, K ;
MASINI, L ;
DIAZRECASENS, J ;
PEARCE, JM ;
WILLSON, K ;
CAMPBELL, S .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (10) :997-1006
[5]   REVERSE FLOW IN THE HUMAN-FETAL DESCENDING AORTA AS A SIGN OF SEVERE FETAL ASPHYXIA PRECEDING INTRAUTERINE DEATH [J].
ILLYES, M ;
GATI, I .
JOURNAL OF CLINICAL ULTRASOUND, 1988, 16 (06) :403-407
[6]  
LAURIN J, 1987, OBSTET GYNECOL, V69, P895
[7]   EFFECTS OF ANESTHESIA ON CEREBRAL ARTERIOLAR RESPONSES TO HYPERCAPNIA [J].
LEVASSEUR, JE ;
KONTOS, HA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01) :H85-H88
[8]  
LINGMAN G, 1986, BIOL NEONATE, V49, P66
[9]  
LINGMAN G, 1986, DOPPLER TECHNIQUES O, P36
[10]   ECHOCARDIOGRAPHIC AND DOPPLER EVALUATION OF THE AORTIC-ARCH AND BRACHIOCEPHALIC VESSELS IN CEREBRAL AND SYSTEMIC ARTERIOVENOUS-FISTULAS [J].
MUSEWE, NN ;
SMALLHORN, JF ;
BURROWS, PE ;
IZUKAWA, T ;
FREEDOM, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (06) :1529-1535