BACTERIAL-COLONIZATION OF ENTERAL FEEDING TUBES

被引:5
作者
ANDERTON, A
NWOGUH, CE
机构
[1] Department of Bioscience & Biotechnology, University of Strothclyde, Glasgow, G1 1XW, Royal College Building
关键词
BACTERIAL COLONIZATION; ENTERAL FEEDING TUBES; ENTERAL FEEDS;
D O I
10.1111/j.1365-277X.1991.tb00108.x
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
An in-vitro model system was used to determine the number of bacteria infused into a 'patient' when three types of polyurethane enteral feeding-tubes that had been experimentally contaminated with feed containing K. aerogenes on day 1, were then perfused with sterile feed for periods of 8 h on three consecutive days (days 2-4). The tubes were syringed with 20 ml sterile water at regular intervals. Viable counts were made on syringe washings, feed collected from the ends of the tubes and feed from the nutrient containers. On day 1, the total number of K. aerogenes in feed samples collected from the nutrient containers and the ends of the tubes rose from 10(2) to 10(3)-10(4) cfu ml-1 over 8 h. On days 2-4 no organisms were detected in the feed samples from the nutrient containers whereas viable counts on feed samples collected from the tubes and syringe washings rose from 10(4) to 10(7) and from 10(1) to 10(7) cfu ml-1 respectively. It can be concluded that a single incidence of feed contamination could lead to a patient receiving contaminated feed from an enteral feeding-tube colonized with bacteria which will not be detected by normal monitoring of the remainder of the system.
引用
收藏
页码:273 / 279
页数:7
相关论文
共 23 条
[1]  
Anderton A., Microbiological aspects of the preparation and administration of naso‐gastric and naso‐enteric feeds in hospitals—a review, Hum. Nutr.: Appl. Nutr., 37 A, pp. 426-440, (1983)
[2]  
Anderton A., The potential of Escherichia coli in enteral feeds to cause food poisoning: a study under simulated ward conditions, J. Hosp. Infect., 5, pp. 155-163, (1984)
[3]  
Anderton A., Scanning electron microscopy of the internal wall topography of enteral feeding tubes, Clinical Nutr., 3, pp. 171-176, (1984)
[4]  
Anderton A., Microbial adhesion: a source of infection in patients fed by enteral feeding tubes, J. Hosp. Infect., 7, pp. 205-208, (1986)
[5]  
Anderton A., Aidoo K.E., The effect of handling procedures on microbial contamination of enteral feeds, J. Hosp. Infect., 11, pp. 364-372, (1988)
[6]  
Anderton A., Howard J.P., Scott D.W., Microbiological control in enteral feeding: a guidance document, (1986)
[7]  
Bourassa M., Cantin M., Sandborn E.B., Pederson E., Scanning electron microscopy of surface irregularities and thrombogenesis of polyurethane and polyethylene coronary catheters, Circulotion, 53, pp. 992-996, (1976)
[8]  
Burman N.P., Colbourne J.S., Techniques for the asssessment of growth of microorganisms on plumbing materials used in contact with potable water supplied, J. App. Bact., 43, pp. 137-144, (1977)
[9]  
Casewell M.W., (1977)
[10]  
Casewell M.W., Bacteriological hazards of contaminated enteral feeds, J. Hosp. Infect., 3, pp. 329-331, (1982)