MR MEASUREMENT OF BLOOD-FLOW IN THE TRUE AND FALSE CHANNEL IN CHRONIC AORTIC DISSECTION

被引:45
作者
CHANG, JM [1 ]
FRIESE, K [1 ]
CAPUTO, GR [1 ]
KONDO, C [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO, MED CTR, DEPT RADIOL, BOX 0628, SAN FRANCISCO, CA 94143 USA
关键词
AORTA; DISSECTION; BLOOD; FLOW DYNAMICS; MAGNETIC RESONANCE IMAGING; CINE MR; TECHNIQUES; HEART;
D O I
10.1097/00004728-199105000-00013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Velocity encoded (VEC) cine MR imaging is a new noninvasive technique for the quantification of blood flow velocity in the cardiovascular system. Six patients with type B aortic dissection underwent VEC cine MR imaging at 1.5 T. This technique provides cine MR magnitude and VEC phase images at approximately 16 equally spaced intervals during an average cardiac cycle. A region of interest encompassing a vascular structure, i.e., false channel, provides a spatially averaged velocity for the time interval at which the image was acquired. Interpretation of velocity values from the 16 intervals during the cardiac cycle provides a temporally average velocity. Velocity mapping across the aortic lumen in these six cases showed average spatial and temporal velocity of 13.4 +/- 1.49 cm/s in the true channel and 3.1 +/- 0.84 cm/s in the false channel (p < 0.05). The peak systolic velocity (temporal peak) was 43.6 +/- 7.20 cm/s in the true channel and 14.3 +/- 2.30 cm/s in the false channel (p < 0.05). The flow volume per cardiac cycle was not significantly different between the ture (23.1 +/- 5.04 ml/cycle) and false channel (27.1 +/- 10.14 ml/cycle). There was substantial retrograde flow in the false channel of two patients. The intraobserver and interobserver variability was < 10% (r = 0.98 to 0.99) for the measurement of flow parameters in both the true and the false channel. We conclude that VEC cine MR imaging demonstrates substantial differences in the hemodynamic pattern in the true and false channel in aortic dissection.
引用
收藏
页码:418 / 423
页数:6
相关论文
共 28 条
  • [1] AMPARO EG, 1984, AM J ROENTGENOL, V143, P1203, DOI 10.2214/ajr.143.6.1203
  • [2] AORTIC DISSECTION - MAGNETIC-RESONANCE IMAGING
    AMPARO, EG
    HIGGINS, CB
    HRICAK, H
    SOLLITTO, R
    [J]. RADIOLOGY, 1985, 155 (02) : 399 - 406
  • [3] MAGNETIC-RESONANCE VELOCITY MAPPING IN AORTIC DISSECTION
    BOGREN, HG
    UNDERWOOD, SR
    FIRMIN, DN
    MOHIADDIN, RH
    KLIPSTEIN, RH
    REES, RSO
    LONGMORE, DB
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726) : 456 - 462
  • [4] THE FUNCTION OF THE AORTA IN ISCHEMIC HEART-DISEASE - A MAGNETIC-RESONANCE AND ANGIOGRAPHIC STUDY OF AORTIC COMPLIANCE AND BLOOD-FLOW PATTERNS
    BOGREN, HG
    MOHIADDIN, RH
    KLIPSTEIN, RK
    FIRMIN, DN
    UNDERWOOD, RS
    REES, SR
    LONGMORE, DB
    [J]. AMERICAN HEART JOURNAL, 1989, 118 (02) : 234 - 247
  • [5] PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION
    BOGREN, HG
    KLIPSTEIN, RH
    MOHIADDIN, RH
    FIRMIN, DN
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    [J]. AMERICAN HEART JOURNAL, 1989, 118 (05) : 990 - 999
  • [6] BLOOD-FLOW - MAGNETIC-RESONANCE IMAGING
    BRADLEY, WG
    WALUCH, V
    [J]. RADIOLOGY, 1985, 154 (02) : 443 - 450
  • [7] MAGNETIC-RESONANCE IMAGING STRATEGIES FOR HEART STUDIES
    CROOKS, LE
    BARKER, B
    CHANG, H
    FEINBERG, D
    HOENNINGER, JC
    WATTS, JC
    MITSUAKI, A
    KAUFMAN, L
    SHELDON, PE
    BOTVINICK, E
    HIGGINS, CB
    [J]. RADIOLOGY, 1984, 153 (02) : 459 - 465
  • [8] DISSECTING ANEURYSM OF AORTA - AORTOGRAPHIC FEATURES AFFECTING PROGNOSIS
    DINSMORE, RE
    WILLERSON, JT
    BUCKLEY, MJ
    [J]. RADIOLOGY, 1972, 105 (03) : 567 - +
  • [9] EFFECTS OF TURBULENCE ON SIGNAL INTENSITY IN GRADIENT ECHO IMAGES
    EVANS, AJ
    BLINDER, RA
    HERFKENS, RJ
    SPRITZER, CE
    KUETHE, DO
    FRAM, EK
    HEDLUND, LW
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (07) : 512 - 518
  • [10] INVIVO VALIDATION OF MR VELOCITY IMAGING
    FIRMIN, DN
    NAYLER, GL
    KLIPSTEIN, RH
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 751 - 756