THE STRENGTH AND STIFFNESS OF THORACIC IMPLANT ANCHORS IN OSTEOPOROTIC SPINES

被引:21
作者
BUTLER, TE [1 ]
ASHER, MA [1 ]
JAYARAMAN, G [1 ]
NUNLEY, PD [1 ]
ROBINSON, RG [1 ]
机构
[1] UNIV KANSAS,MED CTR,ORTHOPED SURG SECT,KANSAS CITY,KS 66160
关键词
BIOMECHANICS; OSTEOPOROSIS; SPINAL IMPLANTS; THORACIC SPINE;
D O I
10.1097/00007632-199409000-00016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective. To gain a better understanding of factors affecting dorsal implant pull-out strength and stiffness so thoracic spinal implant fixation can be improved. Methods. Posterior pull-out testing of six thoracic implant anchor types was performed on 54 osteoporotic human vertebra, T2-10, with an average bone mineral density of 0.67 g/cm(2). Results. The mean loads at neural arch failure were similar (296 to 382 N). Pedicle strength was greatest at T2 and least at T3. Hook claws were stiffer than sublaminar wires (121 N/mm and 180 N/mm versus 42 N/mm and 52 N/mm, respectively). Facet hook and pedicle hook claws were comparable, as were subpars wires. Bone mineral density of the vertebral bodies correlated with the stiffness of the sublaminar wire anchors only. Conclusion. To optimize the strength and stiffness of implant constructs designed to resist forward flexion, this study supports using hook-claws rather than sublaminar wires and extension of fixation to T2 when clinically realistic.
引用
收藏
页码:1956 / 1962
页数:7
相关论文
共 30 条
[1]  
Allen, B.L., Fergusen, R.L., The Galveston technique for L rod instrumentation of the scoliotic spine (1982) Spine, 7, pp. 276-284
[2]  
Asher, M.A., Carson, W.L., Heinig, C.F., Strippgen, W.E., (1990) Isola Spinal System, Principles and Practice, , AcroMed Corporation, Cleveland, Ohio
[3]  
Coe, J.D., Warden, K.E., Herzig, M.A., McAfee, P.C., Influence of bone mineral density on the fixation of thoracolumbar implants A comparative study of transpedicular screws, laminar hooks, and spinous process wires (1990) Spine, 15, pp. 902-907
[4]  
Chapman, T., Harrington rods with sublaminar wires in the treatment of idiopathic scoliosis (1988) Orthopaedic Transactions, 12, 270p
[5]  
Coscia, M.F., Bradford, D.S., Ogilvie, J.W., Scheuermann’s kyphosis: Results in 19 cases treated by spinal arthrodesis and L-rod instrumentation (1988) Orthopaedic Transactions, 12, 255p
[6]  
Cotrel, Y., (1986) New Instrumentation for Surgery of the Spine, , London: Freund Publishing House Ltd
[7]  
Crawford, R.J., Sell, P.J., Ali, M.S., Dove, J., Segmental Spinal Instrumentation, A., Study of the mechanical properties used for sublaminar fixation (1989) Spine, 14, pp. 632-635
[8]  
Eriksson, S., Isberg, B.O., Lindgren, J.U., The usefulness of computed tomography and dual photon absorptiometry in predicting vertebral bone mineral and vertebral strength of the lumbar spine (1988) Transactions of the 34Th Annual Meeting of the Orthopaedic Research Society, 13, 77p
[9]  
Goll, S.R., Balderston, R.A., Stambough, J.L., Booth, R.E., Cohn, J.C., Pickens, G.T., Depth of intraspinal wire penetration during passage of sublaminar wires (1990) Spine, 13, pp. 503-509
[10]  
Haher, T.R., Devlin, V., Freeman, B., Rondon, D., Long-term effects of sublaminar wires on the neural canal (1986), Presented at the Combined Meeting of the Scoliosis Research Society and the British Scoliosis Research Society, Hamilton, Bermuda, September 21-25