ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO

被引:1094
作者
GERTZBEIN, SD [1 ]
ROBBINS, SE [1 ]
机构
[1] UNIV TORONTO,SUNNYBROOK MED CTR,FAC MED,DEPT SURG,TORONTO M4N 3M5,ONTARIO,CANADA
关键词
Angle of insertion; Canal encroachment; Pedicle screw; Point of entry;
D O I
10.1097/00007632-199001000-00004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The accuracy of pedicular screw placement was assessed in 40 consecutive patients treated with the AO “Fixateur Interne.” Postoperative CT scans were used to measure canal encroachment from the medial border of the pedicle, the angle of insertion and the point of entry. Eighty-one percent of the screws were placed within 2 mm of the medial border of the pedicle and 6% had 4-8 mm of canal encroachment with two patients developing minor neurological complications that spontaneously resolved. Four percent were inserted lateral to the pedicle. The parameters linked to satisfactory screw placement include entry point, angle of insertion and pedicular isthmus widths. Improvement in accuracy was noted in the latter 25% of screw insertions, reflecting the learning curve associated with this technique. © Lippincott-Raven Publishers.
引用
收藏
页码:11 / 14
页数:4
相关论文
共 7 条
[1]  
Aebi M., Etter C., Kehl T., Thalgott J., Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system: Indications, techniques and first results of treatment, Spine, 12, pp. 544-551, (1987)
[2]  
Dick W., “The Fixateur Interne" as a versatile implant for spine surgery, Spine, 12, pp. 882-900, (1987)
[3]  
Dick W., Kluger P., Magerl F., Et al., A new device for internal fixation of thoracolumbar and lumbar spine fractures: The “Fixateur Interne.”, Paraplegia, 23, pp. 225-232, (1985)
[4]  
Roy-Camille R., Saillant G., Mazel C., Internal fixation of the lumbar spine with pedicle screw plating, Clin Orthop, 203, pp. 7-17, (1988)
[5]  
Saillant G., Etude anatomique des pedicules vertebraux, applications chirugicales, Rev Chir Orthop Traumatol, 62, pp. 151-157, (1976)
[6]  
Zindrick M., Wiltse L., Domick A., Et al., Analysis of the morphometric characteristics of the thoracic and lumbar pedicles, Spine, 12, pp. 160-166, (1987)
[7]  