USE OF VARIOUS FILTERS FOR GENERATING MODIFIED SUPERCRITICAL-FLUID MOBILE PHASES

被引:6
作者
PYO, D
JU, D
机构
[1] Department of Chemistry, Kangweon National University, Kangweon-do
关键词
SUPERCRITICAL FLUID CHROMATOGRAPHY; SUPERCRITICAL CO2; SUPERCRITICAL CO2 MODIFIERS; MIXING DEVICES FOR POLAR MODIFIERS;
D O I
10.1007/BF02275730
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Adding various components to supercritical carbon dioxide in supercritical fluid chromatography can extend or significantly alter the solvating properties. Polar samples which are difficult to analyze with pure supercritical CO2 because of their high polarity can be separated by addidng polar modifiers. In this paper, a new mixing method using an HPLC filter for adding polar modifier to CO2 is described. Although several filters were tried, only one could keep the amount of modifier in the mobile phase constant for a long time. The amount of water or methanol dissolved in supercritical CO2 was measured by an amperometric microsensor made of a thin film of perfluorosulfonate ionomer (PFSI).
引用
收藏
页码:79 / 82
页数:4
相关论文
共 15 条
[1]   MODIFIER EFFECTS ON RETENTION AND PEAK SHAPE IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BLILIE, AL ;
GREIBROKK, T .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2239-2242
[2]  
CHARPENTIER BA, 1987, ACS SYM SER, V366, P16
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS AND STATIONARY PHASES IN SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
ENGELHARDT, H ;
GROSS, A ;
MERTENS, R ;
PETERSEN, M .
JOURNAL OF CHROMATOGRAPHY, 1989, 477 (01) :169-183
[4]   AMPEROMETRIC MICROSENSOR FOR WATER [J].
HUANG, HL ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1935-1942
[5]  
JENTOFT RE, 1970, J CHROMATOGR SCI, V8, P138
[6]   STUDY OF ADSORPTION OF INSOLUBLE AND SPARINGLY SOLUBLE VAPORS AT GAS-LIQUID INTERFACE OF WATER BY GAS CHROMATOGRAPHY [J].
KARGER, BL ;
CASTELLS, RC ;
SEWELL, PA ;
HARTKOPF, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1971, 75 (25) :3870-&
[7]  
KLESPER E, 1962, J ORG CHEM, V27, P700
[8]   TEMPERATURE AND PRESSURE EFFECTS IN SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
NOVOTNY, M ;
BERTSCH, W ;
ZLATKIS, A .
JOURNAL OF CHROMATOGRAPHY, 1971, 61 (01) :17-&
[9]   ADDITION AND MEASUREMENT OF WATER IN CARBON-DIOXIDE MOBILE PHASE FOR SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
PYO, DN ;
JU, D .
ANALYST, 1993, 118 (03) :253-255
[10]   MODIFIER EFFECTS ON PACKED AND CAPILLARY COLUMNS IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
SCHMIDT, S ;
BLOMBERG, LG ;
CAMPBELL, ER .
CHROMATOGRAPHIA, 1988, 25 (09) :775-780