PERIPHERAL ARTERIOGRAPHY WITH A NEW NONIONIC AGENT - COMPARISON OF IOMEPROL WITH IOPAMIDOL

被引:7
作者
UGOLOTTI, U
LARINI, P
MARCATO, C
CUSMANO, F
PUCCIANTI, F
机构
[1] Istituto di Scienze Radiologiche, Università di Parma, Sezione di Radiologia Vascolare, Padiglione Barbieri, Sala Vascolare, Ospedale Maggiore, Via Gramsci
关键词
CONTRAST MEDIA; EFFICACY STUDY; ANGIOGRAPHY; DSA;
D O I
10.1016/0720-048X(94)90098-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim of this randomized, double-blind, parallel group study was to compare the safety, tolerance and diagnostic efficacy of iomeprol and iopamidol, both at iodine concentration of 150 mgI/ml, in 100 adult patients undergoing peripheral intra-arterial digital subtraction angiography (IA-DSA). All patients underwent extensive pre- and post-contrast clinical, instrumental and laboratory evaluation for safety assessments. The tolerance to the test compounds was evaluated in terms of discomfort associated with the injection of the test compounds. Image quality was prospectively graded by two independent readers according to a five-point scale as 1, insufficient; 2, sufficient; 3, good; 4, excellent; or E, excessive. At the end of the study, two experienced radiologists working at institutions other than the study centre and not aware of patients identity, clinical profile or results of other imaging procedures, jointly evaluated study images using the same ordinal scare. The procedure was always well tolerated. None of the studied patients experienced adverse events. All angiographic examinations were rated as diagnostic. The quality of the radiographs was judged as excellent or good in most individual patient studies, without significant differences between the two study groups. No significant differences between the results of prospective on-site assessment and retrospective external assessment were detected. The results of our study show that iomeprol and iopamidol are equally effective, well tolerated and safe contrast agents when used for peripheral IA-DSA.
引用
收藏
页码:S77 / S82
页数:6
相关论文
共 16 条
[1]  
Almen, Contrast agent design. Some aspect on the synthesis of water soluble contrast agents of low osmolality, Theor Popul Biol, 24, pp. 216-226, (1969)
[2]  
Grainger, Osmolality of intravascular radiologic contrast media, Br J Radiol, 53, pp. 739-746, (1980)
[3]  
Dawson, Pitfield, Grainger, The low osmolality contrast agents. A simple guide, Clin Radiol, 34, pp. 221-226, (1983)
[4]  
Bettmann, The new contrast agents: a perspective, Cardiovascular Intervent Radiol, 9, pp. 173-175, (1986)
[5]  
Dawson, Chemotoxicity of contrast media. A review, Invest Radiol, 20, pp. S84-S91, (1985)
[6]  
Dawson, The physiology and toxicology of low osmolality contrast media, Diagn Imaging, pp. 3-8, (1987)
[7]  
Davies, Felder, Tirone, Iomeprol, Drugs of the future, 15, pp. 1074-1076, (1990)
[8]  
Felder, Gallotti, Favilla, Molecular rearrangement of 5 (a hydroxy alkanoylamino) 2,4,6, triiiodo isophthalic acid amides, Invest Radiol, 23, pp. S101-S105, (1988)
[9]  
Bianco, Conz, Orlando, Gnemi, Berruto, Raffino, Ferrini, Hirsch, Sagami, 4-week repeated intravenous toxicity study and 2-week recovery study of iomeprol in dogs, Prog Med, 12, pp. 1700-1710, (1992)
[10]  
Orlandini, Bertoni, Pellecchi, Aimi, Tirone, Iomeprol in digital angiography in the dog, Obiettivi Veterinari, 5, pp. 33-38, (1990)