DISCONTINUITY CAPACITANCE OF A COAXIAL LINE TERMINATED IN A CIRCULAR WAVEGUIDE

被引:34
作者
RISLEY, EW
机构
[1] Radio Standards Laboratory, National Bureau of Standards, Boulder, Colo.
关键词
D O I
10.1109/TMTT.1969.1126893
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This calculation evaluates the discontinuity capacitance of a coaxial line terminated in a circular waveguide using the Rayleigh-Ritz variational technique. A 50-ohm pinch coaxial line termination with solid center conductor was fabricated with center and outer conductor dimensions of 0.32568±0.00002and 0.74995 ± 0.00002 inches, respec-tively. The measured value of capacitance of this termination at 1000 Hz was 2.164XIO-13 farads as compared with the calculated value of 2.177093 X 10–13farads. Calculated values of capacitance for other line sizes were also compared with measured values and in each case the calculated value agreed with the measured value to within the experimental error of the measured value. © 1969 IEEE. All rights reserved.
引用
收藏
页码:86 / +
页数:1
相关论文
共 6 条
[1]  
BORGNIS FE, 1958, ENCYCL PHYS, V16, P297
[2]  
COLLIN RE, 1960, FIELD THEORY GUIDED, pCH8
[3]  
Courant R., 1953, METHODS MATHEMATICAL
[4]   HALF-ROUND INDUCTIVE OBSTACLES IN RECTANGULAR WAVEGUIDE [J].
KERNS, DM .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION B-MATHEMATICAL SCIENCES, 1960, 64 (02) :113-130
[5]  
MARCUVITZ N, 1950, WAVEGUIDE HANDBOOK, V10
[6]  
Whinnery J. R., 1944, P IRE, V32, P695