COMPARATIVE GAS-PHASE AND PULSED LIQUID-PHASE SEQUENCING ON A MODIFIED APPLIED BIOSYSTEMS 477A SEQUENCER

被引:27
作者
BAUMANN, M
机构
[1] University of Helsinki, Department of Medical Chemistry, 00170 Helsinki 17
关键词
D O I
10.1016/0003-2697(90)90181-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and inexpensive modification of the Applied Biosystems 477A sequencer, to run in the pulsed liquid-phase and in the gas-phase mode of the Edman chemistry, is described. This modification is especially useful for sequencing samples on polyvinylidene difluoride (PVDF) membranes. Additional carriers are required if a sample on a PVDF membrane is sequenced with the pulsed liquid-phase degradation program of the 477A. In the gas-phase mode no such carriers are needed. This eliminates time-consuming preconditioning sequencer cycles and reduces the sequencer background. In addition, initial coupling yields in the gas-phase mode exceeded those in the pulsed liquid-phase mode, whereas the average repetitive yields were similar. Samples spotted onto glass fiber filters pretreated with polybrene and samples spotted or electroblotted onto PVDF membranes were examined. A number of advantages of the gas-phase mode are presented. © 1990.
引用
收藏
页码:198 / 208
页数:11
相关论文
共 24 条
[1]   COVALENT IMMOBILIZATION OF PROTEINS FOR HIGH-SENSITIVITY SEQUENCE-ANALYSIS - ELECTROBLOTTING ONTO CHEMICALLY ACTIVATED GLASS FROM SODIUM DODECYL-SULFATE POLYACRYLAMIDE GELS [J].
AEBERSOLD, RH ;
PIPES, GD ;
NIKA, H ;
HOOD, LE ;
KENT, SBH .
BIOCHEMISTRY, 1988, 27 (18) :6860-6867
[2]  
AEBERSOLD RH, 1986, J BIOL CHEM, V261, P4229
[3]   ISOLATION OF A HUMAN HEPATIC 60-KDA ASPARTYLGLUCOSAMINIDASE CONSISTING OF 3 NON-IDENTICAL POLYPEPTIDES [J].
BAUMANN, M ;
PELTONEN, L ;
AULA, P ;
KALKKINEN, N .
BIOCHEMICAL JOURNAL, 1989, 262 (01) :189-194
[4]   CONVERSION OF THE BECKMAN LIQUID-PHASE SEQUENCER TO A GAS-LIQUID PHASE SEQUENCER [J].
BHOWN, AS ;
WAYLAND, JL ;
LYNN, JD ;
BENNETT, JC .
ANALYTICAL BIOCHEMISTRY, 1988, 175 (01) :39-51
[5]   A NEW SILICONIZED-GLASS FIBER AS SUPPORT FOR PROTEIN-CHEMICAL ANALYSIS OF ELECTROBLOTTED PROTEINS [J].
ECKERSKORN, C ;
MEWES, W ;
GORETZKI, H ;
LOTTSPEICH, F .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1988, 176 (03) :509-519
[6]   A PROTEIN SEQUENATOR [J].
EDMAN, P ;
BEGG, G .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1967, 1 (01) :80-&
[7]  
HEWICK RM, 1981, J BIOL CHEM, V256, P7990
[8]   SOLID-PHASE EDMAN DEGRADATION - AUTOMATIC PEPTIDE SEQUENCER [J].
LAURSEN, RA .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1971, 20 (01) :89-&
[9]   ON THE USE OF POLYETHYLENIMINE AS A CARRIER FOR PROTEIN SEQUENCING - COMPARISON WITH POLYBRENE [J].
LECAER, JP ;
ROSSIER, J .
ANALYTICAL BIOCHEMISTRY, 1988, 169 (02) :246-252
[10]  
LEGENDRE N, 1988, BIOTECHNIQUES, V6, P154