REPEATABILITY OF PERIPHERAL PULSE MEASUREMENTS ON EARS, FINGERS AND TOES USING PHOTOELECTRIC PLETHYSMOGRAPHY

被引:49
作者
JAGO, JR
MURRAY, A
机构
[1] Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne NE7 7DN, United Kingdom
来源
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT | 1988年 / 9卷 / 04期
关键词
Electric Measurements - Photoelectricity--Medical Applications;
D O I
10.1088/0143-0815/9/4/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Peripheral pulses have been recorded and analyzed to determine the accuracy with which pulse transit times (PTTS) can be measured. Measurements of PTT between the ECG Q-wave and various peripheral sites were made in 10 normal subjects on 10 separate days. Mean values were determined for the ears (174 ms), fingers (245 ms), and toes (361 ms). The technique was sufficiently accurate to detect small changes in PTT due to changes in posture; sitting to lying, 5.2 ms. When comparing simultaneous measurements on bilateral sites only small differences in PTT were discovered, and these were not significant in the study group as a whole. However, these differences were significant in some individuals. When the subjects raised a single arm or leg, significant differences (38 ms and 49 ms, respectively) were recorded between sides. The day-to-day repeatability σ of individual PTT measurements on a subject (supine) was for ears, fingers and toes, respectively, 9.4, 9.2 and 12 ms. For right-left differences the repeatability was 7.2, 5.9 and 14 ms. Hence changes in PTTs, or differences between right and left sides can be detected from single measurements with 95% confidence if they exceed approximately 20 ms in ears or fingers and 30 ms in toes.
引用
收藏
页码:319 / 329
页数:11
相关论文
共 19 条
[1]  
ARMITAGE P, 1971, STATISTICAL METHODS, P189
[2]   EFFECTS OF AGING ON ARTERIAL DISTENSIBILITY IN POPULATIONS WITH HIGH AND LOW PREVALENCE OF HYPERTENSION - COMPARISON BETWEEN URBAN AND RURAL COMMUNITIES IN CHINA [J].
AVOLIO, AP ;
DENG, FQ ;
LI, WQ ;
LUO, YF ;
HUANG, ZD ;
XING, LF ;
OROURKE, MF .
CIRCULATION, 1985, 71 (02) :202-210
[3]   A SYSTEM FOR MONITORING THE RADIAL PULSE - APPLICATION TO PULSE TRANSIT-TIME MEASUREMENT [J].
AYLESBURY, LJ ;
MARIE, GV .
PSYCHOPHYSIOLOGY, 1984, 21 (05) :558-561
[4]   RELATIONSHIP BETWEEN PULSE-WAVE VELOCITY AND ARTERIAL ELASTICITY [J].
CALLAGHAN, FJ ;
GEDDES, LA ;
BABBS, CF ;
BOURLAND, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (03) :248-254
[5]   EFFECT OF THE ANATOMICAL STRUCTURE OF THE ARTERIAL TREE ON THE MEASUREMENT OF PULSE-WAVE VELOCITY IN MAN [J].
DELLACORTE, M ;
LOCCHI, F ;
SPINELLI, E ;
SCARPELLI, PT .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :593-599
[6]  
DUTCH J, 1983, NEW ZEAL MED J, V96, P607
[7]   PULSE WAVE VELOCITY IN HEALTHY SUBJECTS AND IN PATIENTS WITH VARIOUS DISEASE STATES [J].
ELIAKIM, M ;
SAPOZNIKOV, D ;
WEINMAN, J .
AMERICAN HEART JOURNAL, 1971, 82 (04) :448-+
[8]   REDUCTION IN PULSE-WAVE VELOCITY AND IMPROVEMENT OF AORTIC DISTENSIBILITY ACCOMPANYING REGRESSION OF ATHEROSCLEROSIS IN THE RHESUS-MONKEY [J].
FARRAR, DJ ;
GREEN, HD ;
WAGNER, WD ;
BOND, MG .
CIRCULATION RESEARCH, 1980, 47 (03) :425-432
[9]   ON A NON-INVASIVE EVALUATION OF PULSE-WAVE VELOCITY IN HUMAN PERIPHERAL ARTERIES [J].
GIZDULICH, P .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1984, 5 (01) :33-36
[10]   AN ARTERIAL TO PERIPHERAL PULSE-WAVE VELOCITY MEASURE [J].
JENNINGS, JR ;
CHOI, S .
PSYCHOPHYSIOLOGY, 1983, 20 (04) :410-418