SEPARATION OF COPOLY(STYRENE ACRYLONITRILE) SAMPLES ACCORDING TO COMPOSITION UNDER REVERSED PHASE CONDITIONS

被引:9
作者
GLOCKNER, G [1 ]
WOLF, D [1 ]
ENGELHARDT, H [1 ]
机构
[1] UNIV SAARLAND,FACHRICHTUNG 113,W-6600 SAARBRUCKEN 11,GERMANY
关键词
COLUMN LIQUID CHROMATOGRAPHY; STYRENE ACRYLONITRILE POLYMERS; GRADIENT ELUTION; SOLUBILITY EFFECTS;
D O I
10.1007/BF02325011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Copoly(styrene/acrylonitrile) samples (S/AN) have been repeatedly separated according to composition by gradient HPLC with alkane hydrocarbons as a starting eluent A and dichloromethane (DCM) or tetrahydrofuran (THF) as a solvent B. In these systems, retention increased with AN content of the copolymers. The chemical nature of the column packings used had almost no influence on the retention of S/AN samples. The present paper shows that n-pentane and n-heptane, when used in a given volumetric gradient with DCM + 20% methanol as a solvent B, lead to identical solution characteristics of S/AN on silica columns. A similar result was obtained on C18 columns with n-heptane or cyclohexane, whereas gradient elution with toluene as a starting eluent caused insufficient resolution. Reversed phase separation of S/AN copolymers could be achieved on polystyrene gel columns through gradients with methanol as a starting eluent and DCM or THF as a solvent B. In both systems, retention decreased with increasing AN content of the copolymers. The elution characteristics were almost linear in the range 0-20 wt% AN. This behaviour can be understood in the context of polymer solubility: in both systems, the solubility borderline of S/AN has a distinct maximum at about 25 wt% AN. Reversed phase separation was achieved at the left hand slope of these curves where the dissolution of a sample with a higher AN content requires less DCM or THF solvent than the dissolution of copolymers which are poorer in AN. This idea predicts that samples with more than 25 wt% AN should elute later than S/AN whose composition is near to the solubility maximum. This indeed was found with a copolymer containing 36.2 wt% AN.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 13 条
[1]  
AUGENSTEIN M, 1990, COMMUNICATION
[2]   HIGH-PERFORMANCE ADSORPTION CHROMATOGRAPHY OF POLYMERS - SEPARATION OF STYRENE ACRYLONITRILE COPOLYMERS ON CN SILICA [J].
DANIELEWICZ, M ;
KUBIN, M ;
VOZKA, S .
JOURNAL OF APPLIED POLYMER SCIENCE, 1982, 27 (09) :3629-3631
[3]   NORMAL-PHASE AND REVERSED-PHASE SEPARATION OF COPOLYMERS PREPARED FROM STYRENE AND ETHYL-METHACRYLATE [J].
GLOCKNER, G .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :280-284
[4]   GRADIENT ELUTION CHROMATOGRAPHY OF POLYMERS ON REVERSED-PHASE COLUMNS WITH TETRAHYDROFURAN AS AN ELUENT COMPONENT [J].
GLOCKNER, G ;
VANDENBERG, JHM .
CHROMATOGRAPHIA, 1984, 19 :55-61
[5]   COPOLYMER FRACTIONATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GLOCKNER, G ;
VANDENBERG, JHM .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :135-144
[6]   HP PRECIPITATION CHROMATOGRAPHY OF STYRENE-ACRYLONITRILE CO-POLYMERS [J].
GLOCKNER, G ;
KROSCHWITZ, H ;
MEISSNER, C .
ACTA POLYMERICA, 1982, 33 (10) :614-616
[7]  
GLOCKNER G, 1984, MACROMOLECULES, V17, P962
[8]   CHARACTERIZATION OF CO-POLYMERS BY MEANS OF LIQUID-CHROMATOGRAPHY [J].
GLOCKNER, G .
PURE AND APPLIED CHEMISTRY, 1983, 55 (10) :1553-1562
[9]  
GLOCKNER G, 1989, J APPL POLYM SCI APP, V43, P39
[10]  
GLOCKNER G, 1971, PLASTE KAUTSCH, V18, P654