DEGRADATIVE BEHAVIOR OF POLYMERIC MATRICES IN (SUB)DERMAL AND MUSCLE-TISSUE OF THE RAT - A QUANTITATIVE STUDY

被引:54
作者
BEUMER, GJ
VANBLITTERSWIJK, CA
PONEC, M
机构
[1] LEIDEN UNIV HOSP, DEPT ENT, OTOBIOL & BIOCOMPATIBIL LAB, 2333 AA LEIDEN, NETHERLANDS
[2] LEIDEN UNIV HOSP, DEPT DERMATOL, BIOMAT RES GRP, 2333 AA LEIDEN, NETHERLANDS
关键词
BIODEGRADATION; SKIN SUBSTITUTE; BIOCOMPATIBILITY;
D O I
10.1016/0142-9612(94)90022-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bilayered matrices, made of synthetic degradable polymers, are developed for use as a dermal regeneration template in large surface area full-thickness skin defects. The porous underlayer is designed to allow ingrowth of dermal components and the dense top layer will serve as a substrate for keratinocytes. Considering the importance of the degradation kinetics of tissue regeneration templates, quantification of matrix degradation up to 1 yr post-implantation, and histological and ultrastructural examination of the implants was performed. In this study a moderate foreign body reaction was observed at both the intramuscular and subcutaneous implantation sites, including the presence of mono- and multinucleated phagocytes. Poly(L-lactic acid) underlayers tended to elicit a stronger cellular infiltrate than co-polymeric ones. In the course of the implantation periods this inflammatory response subsided and neovascular ingrowth and the formation of fibrous tissue in the pores was observed. Matrix degradation was demonstrated, starting with the fragmentation of the constituent polymers into increasingly smaller particles. During the implantation period, fragments showed progressive surface erosion. Poly(L-lactic acid) fragments had a more rounded off appearance as compared to co-polymeric ones. Implant surface area had decreased to less than 20%, 1 yr postimplantation. At both implantation sites and with all matrices, polymer particles were observed inside phagocytic cells. Degradation kinetics were similar with the different matrices. Implants fragmented more rapidly at the subcutaneous implantation site as compared to the intramuscular one. Although the data suggest biomaterial degradation, remnants of matrices could still be retrieved 1 yr postimplantation.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 35 条
[1]   THE BEHAVIOR OF ALLOPLASTIC TYMPANIC MEMBRANES IN STAPHYLOCOCCUS-AUREUS-INDUCED MIDDLE-EAR INFECTION .1. QUANTITATIVE BIOCOMPATIBILITY EVALUATION [J].
BAKKER, D ;
VANBLITTERSWIJK, CA ;
HESSELING, SC ;
DAEMS, WT ;
KUIJPERS, W ;
GROTE, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (06) :669-688
[2]   EFFECT OF IMPLANTATION SITE ON PHAGOCYTE POLYMER INTERACTION AND FIBROUS CAPSULE FORMATION [J].
BAKKER, D ;
VANBLITTERSWIJK, CA ;
HESSELING, SC ;
GROTE, JJ ;
DAEMS, WT .
BIOMATERIALS, 1988, 9 (01) :14-23
[3]  
BAKKER D, 1988, THESIS LEIDEN
[4]  
Beumer G. J., 1993, Clinical Materials, V14, P21, DOI 10.1016/0267-6605(93)90043-7
[5]   CELL-SEEDING AND IN-VITRO BIOCOMPATIBILITY EVALUATION OF POLYMERIC MATRICES OF PEO PBT COPOLYMERS AND PLLA [J].
BEUMER, GJ ;
VANBLITTERSWIJK, CA ;
BAKKER, D ;
PONEC, M .
BIOMATERIALS, 1993, 14 (08) :598-604
[6]  
BEUMER GJ, 1990, ADV BIOMAT, V9, P169
[7]  
BEUMER GJ, IN PRESS J BIOMED MA
[8]   INFLUENCE OF SURFACE CHEMISTRY ON IMPLANT INTERFACE HISTOLOGY - THEORETICAL BASIS FOR IMPLANT MATERIALS SELECTION [J].
CLARK, AE ;
HENCH, LL ;
PASCHALL, HA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (02) :161-174
[9]  
GOGOLEWSKI S, 1992, Clinical Materials, V10, P13, DOI 10.1016/0267-6605(92)90079-9
[10]  
GOODSON WH, 1992, WOUND HEALING BIOCH, P316