FETAL RISKS WITH DEXTRANS DURING DELIVERY

被引:20
作者
BARBIER, P [1 ]
JONVILLE, AP [1 ]
AUTRET, E [1 ]
COUREAU, C [1 ]
机构
[1] HOP BRETONNEAU,DEPT PHARMACO TOXICOVIGILANCE,CTR ANTI POISONS,2 BIS BLVD TONNELLE,F-37044 TOURS,FRANCE
关键词
D O I
10.2165/00002018-199207010-00008
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Epidural analgesia for caesarean section is increasingly used and is gradually replacing general anaesthesia. Hypotension is one of the main risks: preloading of the maternal circulation is used to prevent maternal hypotension and its consequences. For this, various colloid and crystalloid solutions are used. We report a case of maternal anaphylactoid reaction with apparent death in a neonate after dextran administration to the mother. After 100ml of a dextran 40 solution administered intravenously, immediately before an epidural blockade, the mother fainted and developed urticaria and mild respiratory disturbances, without hypotension. At that point dextran infusion was stopped. An apparently dead neonate was rapidly delivered. Immediate and vigorous cardiopulmonary resuscitation was successful. Clonismus appeared 12h later, followed by 3 general epileptic fits treated by phenytoin infusion and subsequently oral phenobarbital. No aetiology was found. After 2 months of treatment, barbiturates were stopped following clinical and electroencephalogram (EEG) improvement. Several similar cases of neonatal disorders resulting from preventive dextran administration during delivery were studied in a national pharmacovigilance survey in France. There were 32 cases reported with moderate maternal anaphylactoid reaction associated with severe acute fetal distress; it is probably advisable to take a cautious approach and avoid preventive fluid preload by dextran administration. Gelatins or crystalloid solutions should be preferred, with intravenous vasopressive amine administered promptly and repeated if necessary should significant maternal hypotension occur during epidural anaesthesia.
引用
收藏
页码:71 / 73
页数:3
相关论文
共 4 条
[1]  
Bodiou C., Bavoux F., Vandel B., Dextrans et accouchement: souffrance foetale majeure, Recherche et Gynécologie, 1, pp. 421-423, (1989)
[2]  
Murray A.M., Morgan M., Whitwam J.G., Crystalloid versus colloid for circulatory preload for epidural Caesarean section, Anaesthesia, 44, pp. 463-466, (1989)
[3]  
Ring J., Messmer K., Incidence and severity of anaphylactoid reactions to colloid volume substitute, Lancet, 1, pp. 466-469, (1977)
[4]  
Rosay H., Lancon J.P., Ferrut O., Gisselmann E., Sgro C., Et al., Accident de type anaphylactique par soluté de dextran chez une parturiente, Cahiers d’Anesthésiologie, 37, pp. 541-542, (1989)