MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW WITH A DOPPLER CATHETER - VALIDATION IN AN ANIMAL-MODEL

被引:24
作者
SUDHIR, K [1 ]
HARGRAVE, VK [1 ]
JOHNSON, EL [1 ]
ALDEA, G [1 ]
MORI, H [1 ]
PORTS, TA [1 ]
YOCK, PG [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,INST CARDIOVASC RES,BOX 0124,SAN FRANCISCO,CA 94143
基金
英国医学研究理事会;
关键词
D O I
10.1016/0002-8703(92)90966-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although Doppler catheter recordings are used to determine coronary flow velocity, their accuracy in the estimation of volumetric blood flow has not been validated. To address this issue, Doppler-derived coronary flow was measured in a canine model and compared with that obtained by means of an electromagnetic flowmeter. A carotid artery-to-circumflex coronary artery shunt was created in six dogs with tubing that incorporated an inline electromagnetic flow device. The circumflex artery was occlusively cannulated by means of a rigid metal stent of known internal diameter, which was placed 2 cm into the vessel, and flow was measured in the stent region by means of a 3F Doppler catheter. Analysis of Doppler shift signals was performed by means of a zero-crossing detector (ZCD) and an off-line fast-Fourier transformation (FFT) system. Flow derived from peak FFT velocities corresponded closely to electromagnetic flow (slope 1.09, r = 0.93), whereas mean FFT and ZCD velocities underestimated electromagnetic flow (with slopes of 0.47 and 0.46, respectively) despite a close correlation (r = 0.92, 0.94). Thus FFT analysis of the Doppler signal with determination of peak velocity gives the most accurate representation of flow, whereas measurements based on ZCD mean velocities may significantly underestimate coronary flow.
引用
收藏
页码:870 / 875
页数:6
相关论文
共 19 条
  • [1] DENARDO SJ, 1992, IN PRESS IEEE T BIOM
  • [2] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [3] FREUDENBERG H, 1981, Z KARDIOL, V70, P863
  • [4] COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES
    GLAGOV, S
    WEISENBERG, E
    ZARINS, CK
    STANKUNAVICIUS, R
    KOLETTIS, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) : 1371 - 1375
  • [5] EFFECTS OF REGIONAL ALPHA-BLOCKADE AND BETA-BLOCKADE ON RESTING AND HYPEREMIC CORONARY BLOOD-FLOW IN CONSCIOUS, UNSTRESSED HUMANS
    HODGSON, JM
    COHEN, MD
    SZENTPETERY, S
    THAMES, MD
    [J]. CIRCULATION, 1989, 79 (04) : 797 - 809
  • [6] ASSESSMENT OF SEVERITY OF CORONARY STENOSES USING A DOPPLER CATHETER - VALIDATION OF A METHOD BASED ON THE CONTINUITY EQUATION
    JOHNSON, EL
    YOCK, PG
    HARGRAVE, VK
    SREBRO, JP
    MANUBENS, SM
    SEITZ, W
    PORTS, TA
    [J]. CIRCULATION, 1989, 80 (03) : 625 - 635
  • [7] ANALYSIS OF FLOW CHARACTERISTICS IN POSTSTENOTIC REGIONS OF THE HUMAN CORONARY-ARTERY DURING BYPASS GRAFT-SURGERY
    KAJIYA, F
    TSUJIOKA, K
    OGASAWARA, Y
    WADA, Y
    MATSUOKA, S
    KANAZAWA, S
    HIRAMATSU, O
    TADAOKA, S
    GOTO, M
    FUJIWARA, T
    [J]. CIRCULATION, 1987, 76 (05) : 1092 - 1100
  • [8] KAJIYA F, 1986, CIRCULATION, V74, P53
  • [9] Lunt M J, 1975, Ultrasound Med Biol, V2, P1, DOI 10.1016/0301-5629(75)90035-6
  • [10] MARCUS ML, 1983, CORONARY CIRCULATION, P25