PHASE-INVERSION CELLULOSE-ACETATE MEMBRANES FOR SUPPRESSION OF PROTEIN INTERFERENCES IN ANODIC-STRIPPING VOLTAMMETRY

被引:15
作者
HOYER, B
JENSEN, N
机构
[1] Department of Chemistry, Aarhus University, 8000 Aarhus C
关键词
D O I
10.1016/0039-9140(95)01481-P
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The phase-inversion (PI) method was used to cast permselective cellulose acetate membranes on glassy carbon electrodes with the aim of suppressing protein interferences in anodic stripping voltammetry (ASV). By using cadmium and lead as test analytes and differential pulse ASV as detection method, it was found that the modification of the electrode greatly reduces the interference from albumin. Cellulose acetate membranes prepared by the PI method give better protection against protein interference and have more reproducible permeability characteristics than membranes of comparable thickness prepared by the base hydrolysis method. An optimization study of the PI coating procedure was undertaken.
引用
收藏
页码:767 / 773
页数:7
相关论文
共 23 条
[1]   EFFECT OF MODEL ORGANIC-COMPOUNDS ON POTENTIOMETRIC STRIPPING ANALYSIS USING A CELLULOSE-ACETATE MEMBRANE-COVERED ELECTRODE [J].
ALDSTADT, JH ;
DEWALD, HD .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :922-926
[2]   EFFECT OF DISSOLVED ORGANICS ON STRIPPING VOLTAMMETRY OF SEAWATER [J].
BATLEY, GE ;
FLORENCE, TM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1976, 72 (01) :121-126
[3]   TRACE-METAL ANALYSIS BY ANODIC-STRIPPING VOLTAMMETRY - EFFECT OF SORPTION BY NATURAL AND MODEL ORGANIC-COMPOUNDS [J].
BREZONIK, PL ;
BRAUNER, PA ;
STUMM, W .
WATER RESEARCH, 1976, 10 (07) :605-612
[4]   COMPARATIVE-STUDY OF POLYMER-COATED MERCURY FILM ELECTRODES FOR VOLTAMMETRIC ANALYSIS OF LEAD AND CADMIUM IN THE PRESENCE OF SURFACTANTS [J].
DAM, MER ;
THOMSEN, KN ;
PICKUP, PG ;
SCHRODER, KH .
ELECTROANALYSIS, 1995, 7 (01) :70-78
[5]   SENSORS FROM POLYMER MODIFIED ELECTRODES [J].
ESPENSCHEID, MW ;
GHATAKROY, AR ;
MOORE, RB ;
PENNER, RM ;
SZENTIRMAY, MN ;
MARTIN, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1051-1070
[6]   NAFION-COATED ELECTRODES WITH HIGH SELECTIVITY FOR CNS ELECTROCHEMISTRY [J].
GERHARDT, GA ;
OKE, AF ;
NAGY, G ;
MOGHADDAM, B ;
ADAMS, RN .
BRAIN RESEARCH, 1984, 290 (02) :390-395
[7]   SIGNAL STABILITY OF NAFION-COATED THIN MERCURY FILM ELECTRODES FOR STRIPPING VOLTAMMETRY [J].
HOYER, B ;
JENSEN, N .
TALANTA, 1994, 41 (03) :449-453
[8]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM ;
BATLEY, GE .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1608-1614
[9]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES TO THE DIRECT DETERMINATION OF TRACE-METALS IN BODY-FLUIDS BY ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2839-2842
[10]   SUPPRESSION OF THE CHLORIDE INTERFERENCE EFFECT ON SOLID-STATE CUPRIC ION-SELECTIVE ELECTRODES BY POLYMER COATING [J].
HOYER, B ;
LOFTAGER, M .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1235-1237