METHODS OF CALIBRATION IN THE DIRECT ANALYSIS OF SOLID SAMPLES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY

被引:16
作者
BERGLUND, M
BAXTER, DC
机构
[1] Department of Analytical Chemistry, University of Umeå
关键词
D O I
10.1016/0584-8547(92)80146-8
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
One of the major problems involved in the direct analysis of solid samples by electrothermal atomic absorption spectrometry (ETAAS) lies in the calibration step because non-spectral interference effects are often pronounced. Three standardization techniques have been described and used in solid sampling-ETAAS: (i) standard additions method; (ii) calibration relative to a certified reference material; and (iii) calibration curve technique. However, an adequate statistical evaluation of the uncertainty in the analyte concentration in the solid sample is most frequently neglected, and reported errors may be seriously underestimated. This can be attributed directly to the complexity of the statistical expressions required to accurately account for errors in each of the calibration techniques mentioned above, and the general lack of relevant reference literature. The object of this work has been to develop a computer package which will perform the necessary statistical analyses of solid sampling-ETAAS data; the result is the program "SOLIDS" described here in the form of an electronic publication in Spectrochimica Acta Electronica, the electronic section of Spectrochimica Acta Part B. The program could also be useful in other analytical fields where similar calibration methods are used. The hard copy text, outlining the calibration models and their associated errors, is accompanied by a diskette containing the program, some data files, and a manual. Use of the program is exemplified in the text, with some of the data files discussed included on the diskette which, together with the manual, should enable the reader to become familiarized with the operation of the program, and the results generated.
引用
收藏
页码:E1567 / E1586
页数:20
相关论文
共 35 条
[1]  
AADLAND E, 1987, FRESEN Z ANAL CHEM, V328, P362
[2]   THE USE OF AN INNER MINIATURE CUP FOR DIRECT DETERMINATION OF POWDERED BIOLOGICAL SAMPLES BY ATOMIC-ABSORPTION SPECTROMETRY [J].
ATSUYA, I ;
ITOH, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (09) :1259-1264
[3]   ON THE DIRECT ANALYSIS OF SOLID SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BAXTER, DC ;
FRECH, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03) :253-263
[5]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[6]  
Box G.E.P., 1987, EMPIRICAL MODEL BUIL
[7]  
BROWN AA, 1987, FRESEN Z ANAL CHEM, V328, P354
[8]   ANALYSES OF SOLID SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING ZEEMAN BACKGROUND CORRECTION [J].
CARNRICK, GR ;
LUMAS, BK ;
BARNETT, WB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (06) :443-447
[9]  
DAVIES OL, 1980, STATISTICAL METHODS
[10]   DETERMINATION OF SILVER IN SILICATE ROCKS BY FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
EAMES, JC ;
MATOUSEK, JP .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1248-1251