OPTIMUM MATCHING OF DIRECT-COUPLED ELECTROMECHANICAL LOADS TO A PHOTOVOLTAIC GENERATOR

被引:12
作者
KHOUZAM, K
KHOUZAM, L
机构
[1] Queensland University Of Technology, School Op Electrical And Electronic Systems Engineering, Gardens Point, Brisbane
关键词
PHOTOVOLTAIC SYSTEM; ELECTROMECHANICAL LOAD COUPLING; LOAD MATCHING;
D O I
10.1109/60.257043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The objective of the paper is to present a general mathematical formulation for matching electromechanical loads connected to a photovoltaic array. An optimization method is then used to solve the matching problem with the objective of maximizing the gross mechanical energy. The analysis is extended to obtain the sizing of the array and the battery in the direct-coupled system. Results show that optimum matching can be achieved by carefully selecting the PV array rated parameters with respect to the load parameters. The rated power of the array is twice that of the load. The field constant that maximizes the gross mechanical energy can be obtained given the parameters of the load and the array temperature. The separately excited motor offers higher matching performance compared to the series motor. The rotodynamic load offers better matching compared to the viscous friction load.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 11 条
[1]   COUPLING OF A VOLUMETRIC PUMP TO A PHOTOVOLTAIC ARRAY [J].
ANIS, WR ;
MERTENS, RP ;
VANOVERSTRAETEN, RJ .
SOLAR CELLS, 1985, 14 (01) :27-42
[3]   DYNAMIC PERFORMANCE OF A DC SHUNT MOTOR CONNECTED TO A PHOTOVOLTAIC ARRAY [J].
FAM, WZ ;
BALACHANDER, MK .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1988, 3 (03) :613-617
[4]  
Gay C. F., 1982, Fourth E.C. Photovoltaic Solar Energy Conference. Proceedings of the International Conference, P335
[5]   DIRECT COUPLING OF PHOTOVOLTAIC POWER SOURCE TO WATER PUMPING SYSTEM [J].
HSIAO, YR ;
BLEVINS, BA .
SOLAR ENERGY, 1984, 32 (04) :489-498
[6]  
Jain P. C., 1988, Solar & Wind Technology, V5, P7, DOI 10.1016/0741-983X(88)90085-9
[7]   OPTIMUM LOAD-MATCHING IN DIRECT-COUPLED PHOTOVOLTAIC POWER-SYSTEMS - APPLICATION TO RESISTIVE LOADS [J].
KHOUZAM, KY .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (02) :265-271
[8]  
KHOUZAM KY, 1989, THESIS ENERGY RES CT
[9]   OPTIMAL SOLAR-ARRAY CONFIGURATION AND DC MOTOR FIELD PARAMETERS FOR MAXIMUM ANNUAL OUTPUT MECHANICAL ENERGY [J].
SAIED, MM ;
JABOORI, MG .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1989, 4 (03) :459-465
[10]  
TOWNSEND T, 1989, JUN P SOLAR 89 ASES, P206