ANATOMICAL LOCALIZATION FOR PET USING MR IMAGING

被引:59
作者
MELTZER, CC
BRYAN, RN
HOLCOMB, HH
KIMBALL, AW
MAYBERG, HS
SADZOT, B
LEAL, JP
WAGNER, HN
FROST, JJ
机构
[1] JOHNS HOPKINS MED INST,DEPT RADIOL,DIV NUCL MED,BALTIMORE,MD 21205
[2] JOHNS HOPKINS MED INST,DEPT RADIOL,DIV NEURORADIOL,BALTIMORE,MD 21205
[3] JOHNS HOPKINS MED INST,DEPT BIOSTAT,BALTIMORE,MD 21205
[4] JOHNS HOPKINS MED INST,DEPT ENVIRONM HLTH SCI,BALTIMORE,MD 21205
[5] JOHNS HOPKINS MED INST,DEPT NEUROSCI,BALTIMORE,MD 21205
[6] JOHNS HOPKINS MED INST,DEPT NEUROL,BALTIMORE,MD 21205
[7] UNIV MARYLAND,PSYCHIAT RES CTR,BALTIMORE,MD 21201
关键词
Anatomy; Atlas and atlases; Brain; Emission computed tomography; Localization; Magnetic resonance imaging Techniques; Techniques;
D O I
10.1097/00004728-199005000-00019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate localization of an imaging plane of interest is often needed prior to a positron emission tomographic (PET) study. We have developed a simple method for accurate and reproducible selection of an imaging plane for PET using magnetic resonance (MR) imaging. This method is useful when optimal sampling of specific brain structures, such as small subcortical nuclei, or when a specific imaging angle is required for the PET study. An external localizing device, consisting of a series of tubes visible on MR, is affixed to an individually fitted thermoplastic mask. This mask system is worn by the patient during both the MR and PET studies. A plane of interest is planned from the sagittal MR image and defined by its relation to the localizing device and to the MR scanner’s “landmark” or reference position. This plane is transferred to the mask by means of a calibrated alignment laser. The coplanar acquisition of MR and PET images allows individualized analysis of brain structure-function relationships. Phantom studies demonstrated the accuracy and reproducibility of imaging plane selection by this method to be within 1 mm and 1°. Application of the localization protocol in a human subject is also presented. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:418 / 426
页数:9
相关论文
共 31 条
[1]   A COMPUTERIZED SYSTEM FOR THE ELASTIC MATCHING OF DEFORMED RADIOGRAPHIC IMAGES TO IDEALIZED ATLAS IMAGES [J].
BAJCSY, R ;
LIEBERSON, R ;
REIVICH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (04) :618-625
[2]   HEAD FIXATION DEVICE FOR REPRODUCIBLE POSITION ALIGNMENT IN TRANSMISSION CT AND POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
BOETHIUS, J ;
ERIKSSON, L ;
GREITZ, T ;
RIBBE, T ;
WIDEN, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (01) :136-141
[3]  
BOHM C, 1983, AM J NEURORADIOL, V4, P731
[4]  
BRINDLEY GS, 1972, J PHYSIOL-LONDON, V225, pP1
[5]   IMAGE NONUNIFORMITY IN MAGNETIC-RESONANCE-IMAGING - ITS MAGNITUDE AND METHODS FOR ITS CORRECTION [J].
CONDON, BR ;
PATTERSON, J ;
WYPER, D ;
JENKINS, PA ;
HADLEY, DM .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (709) :83-87
[6]   SUBTRACTION AUTORADIOGRAPHY OF OPIATE RECEPTOR SUBTYPES IN HUMAN-BRAIN [J].
CROSS, AJ ;
HILLE, C ;
SLATER, P .
BRAIN RESEARCH, 1987, 418 (02) :343-348
[7]  
DRANGOVA M, 1987, THESIS MCGILL MED PH
[8]  
ELSTER A, 1988, CRANIAL MAGNETIC RES
[9]   ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY [J].
EVANS, AC ;
BEIL, C ;
MARRETT, S ;
THOMPSON, CJ ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) :513-530
[10]  
FORST JJ, 1986, TRENDS PHARMACOL SCI, V7, P490