CALIBRATION OF [I-123] IODINE-LABELED TISSUE STANDARDS FOR AUTORADIOGRAPHIC STUDIES

被引:4
作者
JOHNSON, EW
SYBIRSKA, E
ALTIKRITI, M
INNIS, RB
机构
[1] VET ADM MED CTR,PSYCHIAT SERV 116A2,950 CAMPBELL AVE,W HAVEN,CT 06516
[2] YALE UNIV,SCH MED,DEPT PSYCHIAT,NEW HAVEN,CT 06510
关键词
D O I
10.1016/0883-2889(91)90197-9
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Autoradiographic images can be analyzed with computer-assisted microdensitometry relative to radioactive reference standards to provide quantitative measurements of regional radioactivity concentrations. [I-123]Iodine containing sections of brain paste have been calibrated relative to plastic-embedded tritium(H-3) and 125Iodine standards. For exposure times of 8, 12 and 24 h, plastic-embedded standards covered a range concentrations of [I-123]iodine from 1000 to 100,000 dpm/mg wet weight. Iodine-123 radioactivity was linear with section thickness from 5 to 30-mu-m. These studies confirmed the feasibility of using commercially available longer-lived reference standards to provide [I-123]iodine equivalent values in absolute units of dpm (or mu-Ci) per mg tissue.
引用
收藏
页码:1199 / 1201
页数:3
相关论文
共 9 条
[1]   CALIBRATION OF [C-14] PLASTIC STANDARDS FOR QUANTITATIVE AUTORADIOGRAPHY OF [I-125]LABELED LIGANDS WITH AMERSHAM HYPERFILM BETA-MAX [J].
BASKIN, DG ;
WIMPY, TH .
NEUROSCIENCE LETTERS, 1989, 104 (1-2) :171-177
[2]   QUANTITATIVE FILM AUTORADIOGRAPHY FOR TRITIUM - METHODOLOGICAL CONSIDERATIONS [J].
GEARY, WA ;
TOGA, AW ;
WOOTEN, GF .
BRAIN RESEARCH, 1985, 337 (01) :99-108
[3]  
JOHNSON EW, 1989, J NEUROSCI, V9, P2297
[4]  
KUNG HF, 1990, J NUCL MED, V31, P573
[5]   THE USE OF C-14-LABELED TISSUE PASTE STANDARDS FOR THE CALIBRATION OF I-125 LABELED LIGANDS IN QUANTITATIVE AUTORADIOGRAPHY [J].
MILLER, JA ;
ZAHNISER, NR .
NEUROSCIENCE LETTERS, 1987, 81 (03) :345-350
[6]   RECEPTOR AUTORADIOGRAPHY WITH TRITIUM-SENSITIVE FILM - POTENTIAL FOR COMPUTERIZED DENSITOMETRY [J].
PALACIOS, JM ;
NIEHOFF, DL ;
KUHAR, MJ .
NEUROSCIENCE LETTERS, 1981, 25 (02) :101-105
[7]   QUANTITATIVE DENSITOMETRY OF NEUROTRANSMITTER RECEPTORS [J].
RAINBOW, TC ;
BLEISCH, WV ;
BIEGON, A ;
MCEWEN, BS .
JOURNAL OF NEUROSCIENCE METHODS, 1982, 5 (1-2) :127-138
[8]   QUANTITATIVE RECEPTOR AUTORADIOGRAPHY WITH TRITIUM-LABELED LIGANDS - COMPARISON OF BIOCHEMICAL AND DENSITOMETRIC MEASUREMENTS [J].
RAINBOW, TC ;
BIEGON, A ;
BERCK, DJ .
JOURNAL OF NEUROSCIENCE METHODS, 1984, 11 (04) :231-241
[9]  
SYBIRSKA E, 1990, Society for Neuroscience Abstracts, V16, P693