CONSTRUCTION, CALIBRATION, AND APPLICATION OF A COMPACT SPECTROPHOTOMETER FOR EUV (300-A 2500-A) PLASMA DIAGNOSTICS

被引:12
作者
MOOS, HW
CHEN, KI
TERRY, JL
FASTIE, WG
机构
[1] Johns Hopkins University, Physics Department, Baltimore, MD
[2] MIT Francis Bitter National Magnet Laboratory, Cambridge, MA
来源
APPLIED OPTICS | 1979年 / 18卷 / 08期
关键词
D O I
10.1364/AO.18.001209
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A 400-mm normal incidence concave grating spectrophotometer, specifically designed for plasma diagnostics, is described.The wavelength drive, in which the grating is translated as well as rotated, is discussed in detail; the wavelength linearity of the sine drive and methods of improving it are analyzed.The instrument can be used in any orientation, is portable under vacuum, and quite rugged.The construction techniques utilized produce a high quality vacuum making the instrument compatible with both high purity plasma devices and synchrotron radiation sources.The photometric sensitivity calibration was found to be very stable during extended use on high temperature plasma devices.The applications of the instrument to diagnose plasmas in two tokamaks and a mirror device are described.A facility used for photometric calibration of extreme ultraviolet (λ > 300-Å) spectrophotometers against NBS standard diodes is described.The instrumental calibration obtained using this facility was checked by using synchrotron radiation from SURF II; very good agreement was observed.© 1979 Optical Society of America.
引用
收藏
页码:1209 / 1216
页数:8
相关论文
共 20 条
[1]   A VACUUM SPECTROGRAPH FOR THE INFRA-RED [J].
BADGER, RM ;
ZUMWALT, LR ;
GIGUERE, PA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1948, 19 (12) :861-865
[2]   NBS DETECTOR STANDARDS FOR FAR ULTRAVIOLET [J].
CANFIELD, LR ;
JOHNSTON, RG ;
MADDEN, RP .
APPLIED OPTICS, 1973, 12 (07) :1611-1617
[3]  
DRAKE RP, 1978, UCID17864 L LIV LAB
[4]   USE OF SYNCHROTRON RADIATION AS AN ABSOLUTE SOURCE OF VUV RADIATION [J].
EDERER, DL ;
SALOMAN, EB ;
EBNER, SC ;
MADDEN, RP .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1975, 79 (06) :761-774
[5]   SPECTRORADIOMETRIC CALIBRATION TECHNIQUES IN FAR ULTRAVIOLET - STABLE EMISSION SOURCE FOR LYMAN BANDS OF MOLECULAR-HYDROGEN [J].
FASTIE, WG ;
KERR, DE .
APPLIED OPTICS, 1975, 14 (09) :2133-2142
[6]   A SMALL PLANE GRATING MONOCHROMATOR [J].
FASTIE, WG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1952, 42 (09) :641-647
[7]  
MADDEN RP, 1974, XRAY SPECTROSCOPY
[8]  
MOOS HW, 1978, 20 P COSPAR S NEW IN
[9]   CONTINUOUS DISCHARGE LINE SOURCE FOR EXTREME ULTRAVIOLET [J].
PARESCE, F ;
KUMAR, S ;
BOWYER, CS .
APPLIED OPTICS, 1971, 10 (08) :1904-&
[10]   BROAD-BAND STABLE DETECTOR FOR ULTRAVIOLET (300-1700-A) PLASMA SPECTROSCOPY [J].
RICHARDS, RK .