ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT

被引:75
作者
DEKEMP, RA
NAHMIAS, C
机构
[1] Department of Physics, McMaster University, Hamilton, Ontario
关键词
PET; POSITRON EMISSION TOMOGRAPHY; ATTENUATION CORRECTION; SINGLE PHOTON; TRANSMISSION;
D O I
10.1118/1.597394
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of single photon transmission measurement with a rotating rod source has been evaluated to measure the attenuation correction factors in positron emission tomography (PET). The singles projections are resampled into the coincidence geometry using the detector positions and the rod source location. A nonparalyzable dead time correction algorithm was developed for the block detectors used in the McMaster PET scanner. This enables accurate attenuation correction factors (ACFs) to be computed using a wide range of source strengths for transmission scanning. Transaxial resolution is approximately 6 mm, which is comparable to emission scanning performance. Axial resolution is about 25 mm, with only crude source collimation. ACFs are underestimated by as much as 10% due to increased cross-plane scatter, compared to coincidence transmission accuracy. The response of the correction factors to object density is within 15%, when comparing singles transmission measurement to current coincidence transmission measurement. The major advantage of using singles transmission measurement is a dramatically increased count rate. A factor of 7 increase in count rate over coincidence scanning is possible with a 2-mCi transmission rod source. Uniformity of 2% in the transmission images is possible with this source strength and a 2-min acquisition. There are no randoms counted in singles transmission scans, which makes the measured count rate vary linearly with source activity. Singles detector dead time losses are approximately 6% in the detectors opposite a 2-mCi rod source.
引用
收藏
页码:771 / 778
页数:8
相关论文
共 10 条
[1]  
[Anonymous], ATOMIC NUCLEUS
[2]   THE ELECTRONICS FOR THE DONNER 600-CRYSTAL POSITRON TOMOGRAPH [J].
CAHOON, JL ;
HUESMAN, RH ;
DERENZO, SE ;
GEYER, AB ;
UBER, DC ;
TURKO, BT ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :570-574
[3]  
CAROLL LR, 1983, SNM, P235
[4]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[5]  
DEKEMP R, 1992, IEEE ENG MED BIOL SO, V14, P1825
[6]   A REAL-TIME DIGITAL COINCIDENCE PROCESSOR FOR POSITRON EMISSION TOMOGRAPHY [J].
DENT, HM ;
JONES, WF ;
CASEY, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :556-559
[7]  
DERENZO SE, 1975, J NUCL MED, V16, P1166
[8]  
JOHNS HE, 1971, PHYSICS RADIOLOGY, P744
[9]   MEASURING PET SCANNER SENSITIVITY - RELATING COUNTRATES TO IMAGE SIGNAL-TO-NOISE RATIOS USING NOISE EQUIVALENT COUNTS [J].
STROTHER, SC ;
CASEY, ME ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :783-788
[10]   ANALYSIS OF OPTIMUM DIAMETER OF ORBIT OF TRANSMISSION-LINE SOURCE IN POSITRON EMISSION TOMOGRAPH [J].
YAMAMOTO, S ;
IIDA, H ;
AMANO, M ;
MIURA, S ;
HIROSE, Y ;
KANNO, I .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1017-1020