DEVELOPMENT OF 500-KV XLPE CABLES AND ACCESSORIES FOR LONG-DISTANCE UNDERGROUND TRANSMISSION-LINE .1. INSULATION DESIGN OF CABLES

被引:39
作者
KUBOTA, T
TAKAHASHI, Y
SAKUMA, S
WATANABE, M
KANAOKA, M
YAMANOUCHI, H
机构
[1] FURUKAWA ELECT CORP LTD,CHIBA,JAPAN
[2] SUMITOMO ELECT IND LTD,OSAKA,JAPAN
[3] HITACHI CABLE LTD,POWER SYST LAB,HITACHI,JAPAN
[4] FUJIKURA LTD,TOKYO,JAPAN
关键词
D O I
10.1109/61.329507
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses the results of a basic study for the development of 500-kV XLPE cables. The authors have established that the factors that decide the performance of today's XLPE cables are impurities in the insulator and protrusions on the semiconductive layer, and that the insulation performance of XLPE cables is determined by the size of these defects. In model tests of XLPE cables, the minimum insulation breakdown stress of cables was determined, to set the design values for 500-kV XLPE cable. As a result, it was found that it is possible to design cables having an insulation thickness of 25 mm.
引用
收藏
页码:1741 / 1749
页数:9
相关论文
共 12 条
  • [1] PHYSICAL MODEL OF ELECTRIC AGING AND BREAKDOWN OF EXTRUDED POLYMERIC INSULATED POWER-CABLES
    BAHDER, G
    GARRITY, T
    SOSNOWSKI, M
    EATON, R
    KATZ, C
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (06): : 1379 - 1390
  • [2] FUKUNAGA S, 1990, 1990 IEEE EI S
  • [3] STATISTICAL CONSIDERATIONS ON IMPULSE BREAKDOWN CHARACTERISTICS OF CROSSLINKED POLYETHYLENE INSULATED CABLES
    KANEKO, R
    SUGIYAMA, K
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (02): : 367 - 377
  • [4] KREUGER FH, 1968, CIGRE 1968
  • [5] MUTO H, 1991, 1991 CEIDP
  • [6] OGAWA K, 1989, 1989 IEEJ NAT CONV, P1459
  • [7] OUDIN JM, 1962, CIGRE 1962
  • [8] SUZUKI H, 1990, 1990 CEIDP
  • [9] TANAKA H, 1992, 1992 CEIDP
  • [10] TANAKA H, 1990, 1990 IEEJ NAT CONV, P1378