IMPACT OF OPTIMIZED TREATMENT PLANNING FOR TANDEM AND RING, AND TANDEM AND OVOIDS, USING HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL-CANCER

被引:28
作者
NOYES, WR
PETERS, NE
THOMADSEN, BR
FOWLER, JF
BUCHLER, DA
STITT, JA
KINSELLA, TJ
机构
[1] UNIV WISCONSIN,SCH MED,DEPT OBSTET & GYNECOL,MADISON,WI
[2] UNIV WISCONSIN,SCH MED,DEPT MED PHYS,MADISON,WI
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 31卷 / 01期
关键词
HIGH DOSE RATE; BRACHYTHERAPY; OPTIMIZE; CERVICAL CANCER;
D O I
10.1016/0360-3016(94)00401-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Different treatment techniques are used in high dose rate (HDR) remote afterloading intracavitary brachytherapy for uterine cervical cancer. We have investigated the differences between ''optimized'' and ''nonoptimized'' therapy using both a tandem and ring (T/R) applicator, and a tandem and ovoids (T/O), applicator. Methods and Materials: HDR afterloading brachytherapy using the Madison System for Stage IB cervical cancer was simulated for 10 different patients using both a T/R applicator and a T/O applicator. A treatment course consists of external beam irradiation and five insertions of HDR afterloading brachytherapy. Full dosimetry calculations were performed at the initial insertion for both applicators and used as a reference for the following four insertions of the appropriate applicator. Forty dosimetry calculations were performed to determine the dose delivered to Point M (similar to Point A), Point E (obturator lymph nodes), vaginal surface, bladder, and rectum. ''Optimized'' doses were specified to Point M and to the vaginal surface. ''Nonoptimized'' doses were specified to Point M only. Using the linear-quadratic equation, calculations have been performed to convert the delivered dose using HDR to the biologically equivalent doses at the conventional low dose rate (LDR) at 0.60 Gy/h. Results: Major differences between ''optimized'' and ''nonoptimized'' LDR equivalent doses were found at the vaginal surface, bladder, and rectum. Overdoses at the vaginal surface, bladder, and rectum were calculated to be 208%, nil, and 42%, respectively, for the T/R applicator with ''nonoptimization.'' However, for the T/O applicator, the overdoses were smaller, being nil, 32%, and 27%, respectively, with ''nonoptimization.'' Conclusion: Doses given in high dose rate intracavitary brachytherapy border on tissue tolerance. ''Optimization'' of either applicator decreases the risk of a dose that may have potential for complications. Optimization of a tandem and ovoids best ensures that the doses are not diminished at the treatment sites, and that the potential for overdose is reduced.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 11 条
[1]  
CHASSAGNE D, 1977, J RADIOL ELEC MED N, V58, P387
[3]  
FOWLER JF, 1990, BRACHYTHERAPY, P121
[4]   THE LINEAR-QUADRATIC FORMULA AND PROGRESS IN FRACTIONATED RADIOTHERAPY [J].
FOWLER, JF .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (740) :679-694
[5]   AN ANALYSIS OF THE EFFICACY AND SAFETY OF HIGH-DOSE-RATE AS COMPARED TO LOW-DOSE RATE BRACHYTHERAPY IN THE TREATMENT OF UTERINE CERVICAL-CARCINOMA [J].
HARTMANN, TJ ;
SARKARIA, JN ;
PETEREIT, DG ;
STITT, JA ;
BUCHLER, DA ;
CHAPPELL, R ;
FOWLER, JF ;
KINSELLA, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 :130-130
[6]   RECOVERY FROM RADIATION-DAMAGE IN HUMAN SQUAMOUS CARCINOMA OF THE CERVIX [J].
KELLAND, LR ;
STEEL, GG .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1989, 55 (01) :119-127
[7]   HIGH-DOSE RATE INTRACAVITARY BRACHYTHERAPY FOR CARCINOMA OF THE CERVIX - THE MADISON SYSTEM .1. CLINICAL AND RADIOBIOLOGICAL CONSIDERATIONS [J].
STITT, JA ;
FOWLER, JF ;
THOMADSEN, BR ;
BUCHLER, DA ;
PALIWAL, BP ;
KINSELLA, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (02) :335-348
[8]   HIGH-DOSE RATE INTRACAVITARY BRACHYTHERAPY FOR CARCINOMA OF THE CERVIX - THE MADISON SYSTEM .2. PROCEDURAL AND PHYSICAL CONSIDERATIONS [J].
THOMADSEN, BR ;
SHAHABI, S ;
STITT, JA ;
BUCHLER, DA ;
FOWLER, JF ;
PALIWAL, BR ;
KINSELLA, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (02) :349-357
[9]  
Tod MC, 1938, BRIT J RADIOL, V11, P809
[10]  
WITHERS HR, 1982, PROGR RADIO ONCOLOGY, V2, P287