MAGNETIC-RESONANCE FOR THE ANESTHETIST .1. PHYSICAL PRINCIPLES, APPLICATIONS, SAFETY ASPECTS

被引:34
作者
MENON, DK
PEDEN, CJ
HALL, AS
SARGENTONI, J
WHITWAM, JG
机构
[1] Hammersmith Hospital, London, W12 0HS, Du Cane Road
[2] Hammersmith Hospital, London, W12 0HS, Du Cane Road
[3] Hammersmith Hospital, London, W12 0HS, Du Cane Road
[4] NMR Unit, Hammersmith Hospital, London, W12 0HS, Du Cane Road
[5] Hammersmith Hospital, London, W12 0HS, Du Cane Road
关键词
MEASUREMENT TECHNIQUES; NUCLEAR MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; MAGNETIC RESONANCE SPECTROSCOPY;
D O I
10.1111/j.1365-2044.1992.tb02130.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Anaesthetists are being increasingly involved in magnetic resonance (MR) procedures, both in patient care and as a research tool. This paper outlines the physical basis of nuclear magnetic resonance and describes its application in magnetic resonance imaging and spectroscopy. Principles of magnet design and safety relevant to anaesthetic practice in a magnetic resonance environment are discussed and guidelines for anaesthetic practice suggested. Some recent clinical magnetic resonance studies of anaesthetic interest are reviewed. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:240 / 255
页数:16
相关论文
共 49 条
[1]   MAPPING OF METABOLITES IN WHOLE ANIMALS BY P-31 NMR USING SURFACE COILS [J].
ACKERMAN, JJH ;
GROVE, TH ;
WONG, GG ;
GADIAN, DG ;
RADDA, GK .
NATURE, 1980, 283 (5743) :167-170
[2]   TISSUE INTERACTIONS WITH NONIONIZING ELECTROMAGNETIC-FIELDS [J].
ADEY, WR .
PHYSIOLOGICAL REVIEWS, 1981, 61 (02) :435-514
[3]   PROGNOSIS OF NEWBORN-INFANTS WITH HYPOXIC-ISCHEMIC BRAIN INJURY ASSESSED BY PHOSPHORUS MAGNETIC-RESONANCE SPECTROSCOPY [J].
AZZOPARDI, D ;
WYATT, JS ;
CADY, EB ;
DELPY, DT ;
BAUDIN, J ;
STEWART, AL ;
HOPE, PL ;
HAMILTON, PA ;
REYNOLDS, EOR .
PEDIATRIC RESEARCH, 1989, 25 (05) :445-451
[4]   NUCLEAR MAGNETIC-RESONANCE STUDIES OF ANESTHETIC INTERACTIONS WITH HEMOGLOBIN [J].
BARKER, RW ;
BROWN, FF ;
DRAKE, R ;
HALSEY, MJ ;
RICHARDS, RE .
BRITISH JOURNAL OF ANAESTHESIA, 1975, 47 (01) :25-29
[6]  
BEISCHER DE, 1964, AEROSPACE MED, V35, P939
[7]   COMBINED APPLICATION OF MR IMAGING AND SPECTROSCOPY IN NEONATES AND CHILDREN - INSTALLATION AND OPERATION OF A 2.35-T SYSTEM IN A CLINICAL SETTING [J].
BOESCH, C ;
MARTIN, E .
RADIOLOGY, 1988, 168 (02) :481-488
[8]   NUCLEAR MAGNETIC-RESONANCE (NMR) INVIVO STUDIES - KNOWN THRESHOLDS FOR HEALTH-EFFECTS [J].
BUDINGER, TF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (06) :800-811
[9]  
Coutts G A, 1989, NMR Biomed, V1, P190, DOI 10.1002/nbm.1940010407
[10]   CHANGES IN CARDIAC EXCITABILITY AND VULNERABILITY IN NMR FIELDS [J].
DOHERTY, JU ;
WHITMAN, GJR ;
ROBINSON, MD ;
HARKEN, AH ;
SIMSON, MB ;
SPEAR, JF ;
JOSEPHSON, ME .
INVESTIGATIVE RADIOLOGY, 1985, 20 (02) :129-135