DOSE REDUCTION IN DENTAL RADIOGRAPHY

被引:33
作者
HORNER, K
HIRSCHMANN, PN
机构
[1] DENTAL HOSP LEEDS,CLARENDON WAY,LEEDS LS2 9LU,ENGLAND
[2] UNIV MANCHESTER,HOSP DENT,TURNER DENTAL SCH,DEPT ORAL MED,MANCHESTER M13 9PL,LANCS,ENGLAND
关键词
Dental radiography; Panoramic radiography; Radiation protection;
D O I
10.1016/0300-5712(90)90106-O
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
All exposures to ionizing radiation for medical and dental purposes carry risks to both the patient and staff. It is now accepted practice that all exposures should be kept as low as reasonably practicable to minimize these risks. The various methods currently available for dose limitation in intraoral and panoramic radiography and their effects on image quality are considered. In intraoral radiography the use of fast (E-speed) film and rectangular collimation offer dose reductions of approximately 50 per cent and 60 per cent respectively. Constant potential X-ray units, longer focus-to-skin distances and rare-earth filtration will permit further dose reductions. In panoramic radiography the radiation dose to the patients can be reduced by up to one-eighth by combining the use of constant potential X-ray units, rare-earth intensifying screens and rare-earth filtration. © 1990.
引用
收藏
页码:171 / 184
页数:14
相关论文
共 117 条
[1]   PATIENT EXPOSURES FROM INTRAORAL RADIOGRAPHIC EXAMINATIONS [J].
ALCOX, RW ;
JAMESON, WR .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1974, 88 (03) :568-579
[2]  
ARNOLD LV, 1983, THESIS BRUSSELS, P93
[3]  
CATANDELLAFLETC.J, 1987, ORAL SURG ORAL MED O, V63, P94
[4]   DIAGNOSTIC QUALITY VERSUS PATIENT EXPOSURE WITH 5 PANORAMIC SCREEN-FILM COMBINATIONS [J].
DAMBROSIO, JA ;
SCHIFF, TG ;
MCDAVID, WD ;
LANGLAND, OE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 61 (04) :409-411
[5]   EVALUATION OF NEW RADIOGRAPHIC SCREENS FOR INTRA-ORAL RADIOGRAPHY [J].
DAWOOD, FF ;
MANSONHING, LR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1979, 48 (02) :178-186
[6]   RADIOGRAPHIC QUALITY-CONTROL MEASUREMENTS COMPARING D-SPEED FILM, E-SPEED FILM, AND XERORADIOGRAPHY [J].
DIEHL, R ;
GRATT, BM ;
GOULD, RG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 61 (06) :635-640
[7]   CLINICAL-EVALUATION OF EKTASPEED X-RAY-FILM FOR USE IN ENDODONTICS [J].
DONNELLY, JC ;
HARTWELL, GR ;
JOHNSON, WB .
JOURNAL OF ENDODONTICS, 1985, 11 (02) :90-94
[8]  
DWEIT JD, 1986, DENTOMAXILLOFAC RADI, V15, P45
[9]   EVALUATION OF ALUMINUM-YTTRIUM FILTRATION FOR INTRAORAL RADIOGRAPHY [J].
FARMAN, AG ;
PEREZ, C ;
JACOBSON, A ;
KELLY, MS .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 67 (02) :224-226
[10]   ULTRASPEED VERSUS EKTASPEED X-RAY-FILM - ENDODONTISTS PERCEPTIONS [J].
FARMAN, AG ;
MENDEL, RW ;
VONFRAUNHOFER, JA .
JOURNAL OF ENDODONTICS, 1988, 14 (12) :615-619