HIGH-FREQUENCY AUDIOMETRIC MONITORING STRATEGIES FOR EARLY DETECTION OF OTOTOXICITY

被引:84
作者
FAUSTI, S
LARSON, VD
NOFFSINGER, D
WILSON, RH
PHILLIPS, DS
FOWLER, CG
机构
[1] DEPT VET AFFAIRS MED CTR, PORTLAND, OR USA
[2] OREGON HLTH SCI UNIV, DEPT OTOLARYNGOL, PORTLAND, OR 97201 USA
[3] DEPT VET AFFAIRS MED CTR, AUGUSTA, GA USA
[4] DEPT VET AFFAIRS MED CTR, LONG BEACH, CA USA
[5] DEPT VET AFFAIRS MED CTR, LOS ANGELES, CA USA
[6] DEPT VET AFFAIRS MED CTR, MOUNTAIN HOME, TN USA
[7] UNIV S CAROLINA, DEPT COMMUN, COLUMBIA, SC 29208 USA
[8] UNIV CALIF LOS ANGELES, SCH MED, DEPT SURG, DIV HEAD & NECK SURG, LOS ANGELES, CA USA
[9] E TENNESSEE STATE UNIV, DEPT SURG, JOHNSON CITY, TN 37614 USA
[10] E TENNESSEE STATE UNIV, DEPT COMMUN DISORDERS, JOHNSON CITY, TN 37614 USA
[11] OHSU, DEPT MED PSYCHOL, PORTLAND, OR USA
[12] UNIV CALIF IRVINE, DEPT OTOLARYNGOL HEAD & NECK SURG, IRVINE, CA 92717 USA
关键词
D O I
10.1097/00003446-199406000-00004
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Therapeutic drugs such as the aminoglycoside antibiotics (AMG) and the chemotherapy agent cisplatin (CDDP) are known to cause irreversible hearing loss, typically affecting highest frequency hearing first with progression of loss to the lower frequency regions. Conventional (0.25-8 kHz) and high-frequency (9-20 kHz) serial hearing threshold monitoring was done in 123 hospitalized patients (222 ears) administered AMG or CDDP. Of ears showing a decrease in sensitivity corresponding with treatment, 62.5% demonstrated initial hearing loss solely in the high-frequency range, 13.5% first showed loss only in the conventional-frequency range, and 24.0% showed loss in both frequency ranges concurrently. Thus, if only high frequencies had been monitored, early change in auditory sensitivity would have been detected in 86.5% of these patients. Further analysis revealed a range of five frequencies, specific to each individual's hearing threshold configuration, in which initial ototoxicity appeared most likely to be detected. Testing only these five frequencies would have identified 89.2% of ears that showed change. The results of this study confirm the need to serially monitor auditory thresholds, especially in the high-frequency range, of patients receiving ototoxic drugs. A shortened five-frequency monitoring protocol is presented and suggested for use with patients unable to tolerate lengthy audiometric testing procedures.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 30 条
[1]   AUDITORY TOXICITY EFFECTS OF LONG-TERM CIS-DICHLORODIAMMINEPLATINUM-II THERAPY IN GENITOURINARY CANCER-PATIENTS [J].
AGUILARMARKULIS, NV ;
BECKLEY, S ;
PRIORE, R ;
METTLIN, C .
JOURNAL OF SURGICAL ONCOLOGY, 1981, 16 (02) :111-123
[2]  
ATHERLEY GR, 1963, BRIT J IND MED, V20, P231
[3]   DRUG-INDUCED OTOTOXICITY [J].
BRUMMETT, RE .
DRUGS, 1980, 19 (06) :412-428
[4]   PREFERRED METHOD FOR CLINICAL DETERMINATION OF PURE-TONE THRESHOLDS [J].
CARHART, R ;
JERGER, JF .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1959, 24 (04) :330-345
[5]  
DOBIE RA, 1983, LARYNGOSCOPE, V93, P906
[6]  
DRESCHLER WA, 1989, AUDIOLOGY, V28, P211
[7]  
Fausti S A, 1990, J Am Acad Audiol, V1, P162
[8]  
FAUSTI SA, 1993, ARCH OTOLARYNGOL, V119, P661
[9]   SYSTEM FOR EVALUATING AUDITORY FUNCTION FROM 8000-20000-HZ [J].
FAUSTI, SA ;
FREY, RH ;
ERICKSON, DA ;
RAPPAPORT, BZ ;
CLEARY, EJ ;
BRUMMETT, RE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1979, 66 (06) :1713-1718
[10]   HIGH-FREQUENCY AUDIOMETRIC MONITORING FOR EARLY DETECTION OF AMINOGLYCOSIDE OTOTOXICITY [J].
FAUSTI, SA ;
HENRY, JA ;
SCHAFFER, HI ;
OLSON, DJ ;
FREY, RH ;
MCDONALD, WJ .
JOURNAL OF INFECTIOUS DISEASES, 1992, 165 (06) :1026-1032